10 - 10 Symbol MiniScan MSXX07 Series Integration Guide

Laser On Time
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in
0.1 second increments from 0.5 to 9.9 seconds.
To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on page 10-93 that
correspond to the desired on time. Include a leading zero for times less than 1.0 se cond. For example, to set an on
time of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To change the selection or to
cancel an incorrect entry, scan the Cancel bar code on page 10-95.
Laser On Time
Scan Angle
This parameter sets the scan angle to the default or alternate angle.
*Default Angle
Alternate Angle
NOTE This option is supported by the Symbol MS1207FZY only.