Moxa Technologies C104H/PCI Series user manual Connection Cable and Cable Wiring

Models: C104H/PCI Series

1 64
Download 64 pages 23.71 Kb
Page 51
Image 51

Connection Cable and Cable Wiring

Opt4D

PC COM2 port, Serial Printer,

Terminal, or any DTE Device

C104H/PCI

 

 

 

DTE Device

DB9 Male

 

 

 

DB25 Male

RxD

2

2

TxD

TxD

3

3

RxD

CTS

8

4

RTS

RTS

7

5

CTS

DTR

4

6

DSR

DSR

6

 

20

DTR

 

GND

5

7

GND

DCD

1

8

DCD

Type 2: To connect C104H/PCI Series to a DCE device.

Opt4C

Straight-through Cable

Modem,

or any DCE Device

C104H/PCI

 

 

 

DCE Device

DB25 Male

 

 

 

DB25 Female

TxD

2

2

RxD

RxD

3

 

3

TxD

 

RTS

4

4

CTS

CTS

5

5

RTS

DSR

6

6

DTR

DTR

20

20

DSR

GND

7

 

7

GND

 

DCD

8

8

DCD

Smartio C104H/PCI Series User’s Manual 5-3

Page 51
Image 51
Moxa Technologies user manual Connection Cable and Cable Wiring, Type 2 To connect C104H/PCI Series to a DCE device