Moxa Technologies C104H/PCI Series user manual Gnd Rts Cts Dsr Dtr Dcd

Models: C104H/PCI Series

1 64
Download 64 pages 23.71 Kb
Page 52
Image 52

Opt4D

C104H/PCI

 

 

DB9 Male

 

 

RxD

2

2

TxD

3

3

CTS

8

4

RTS

7

5

DTR

4

6

DSR

6

20

GND

5

7

DCD

1

8

Modem

or any DCE Device

DCE Device DB25 Female RxD

TxD

CTS

RTS

DTR

DSR

GND

DCD

Type 3: To connect C104H/PCI Series to a DTE with 3-pin wiring.

If the Hardware flow control feature is set to ON, you must loop back (or short) the RTS with CTS and DSR with DTR, DCD on MOXA site, indicated in dash- lines of the following diagrams. If the Hardware flow control feature is set to OFF, you could just leave RTS, CTS, DSR, DTR, DCD open, ignoring the connection indicated in dash-lines.

Opt4C

PC COM2 port, Serial Printer,

Terminal, or any DTE Device

C104H/PCI

 

 

DTE Device

DB25 Male

 

 

DB25 Male

TxD

2

2

TxD

RxD

3

3

RxD

GND

7

7

GND

RTS

4

4

RTS

CTS

5

5

CTS

DSR

6

6

DTR

DTR

20

20

DSR

DCD

8

8

DCD

5-4Smartio C104H/PCI Series User’s Manual