4.Check the Auto Enumerating COM Name check-box to assign continuous COM numbers for subsequent ports. For example, if COM3 is assigned to Port 1, then COM4 will be automatically assigned to Port 2.

5.Re-assign the Rx FIFO Trigger by selecting a number from the pull-down list. Check the Set the change to all ports check-box to apply this setting to all ports. Rx FIFO trigger levels from 1 to 62 bytes are available, with a default value of 56 bytes.

6.Re-assign the Tx FIFO Size by selecting a number from the pull-down list. Check the Set the change to all ports check-box to apply this setting to all ports. Tx FIFO sizes from 1 to 64 bytes are available, with a default value of 64 bytes.

7.To complete the update, click [OK] in the Port X dialog box, click [OK] in the CP- 168U board Properties dialog box, and then click [OK] on the Device Manager tab.

8.Restart the system to activate the latest configuration.

Updating the Driver

This section shows how to update the Windows 95/98 driver.