INSTALLATION
Plumbing Connections
CAUTION:
!Plumbing connections must comply with local sanitary and plumbing codes.
Water Connections
1.Connect the hot water supply (140oF/60oC Min) to the fill solenoid valve (located behind the front panel). The fill solenoid valve is equipped with a flow control that will accept water pressures from 20 psi to 70 psi.
2.Install a manual
3.The fill solenoid valve is equipped with a
Drain Connections
1.Your Moyer Diebel glasswasher is supplied with a flexible 5/8" I.D. drain hose, which must be connected to a
Detergent
1.Use a qualified detergent/chemical supplier for your detergent, rinse aid, and chemical sanitizer needs.
2.Your machine is supplied with a chemical dispensing system that is internally wired and ready for use. Insert the labeled Chemical pickup tubes into the correct containers. The pickup tubes have a strainer on the end to prevent crystallized chemical from clogging the supply lines.
3.The cycle timer located in the main control cabinet is equipped with adjustable cams for the chemical dispensing pump(s). The cams control the length of time that the pumps operate. A qualified person should adjust the cam settings if necessary. Refer to the timer chart diagram(s) at the end of the manual for timer cam locations and factory time settings.
NOTE:
A nonchlorinated, nonfoaming commercial detergent is recommended for your glasswasher.
Rinse Aid
1.Using a liquid rinse aid, insert the labeled Rinse Aid pickup tube into the rinse aid container.
Chemical Sanitizer
1.Using a 5.25% or 8.4% sodium hypochlorite solution, insert the labeled Chemical Sanitizer pickup tube into the chemical sanitizer container.
2.Contact your chemical supplier for adjustment of the chemical sanitizer.
6