Chemical Connections (Cont.)

INSTALLATION

Chemical Connections (Cont.)

Refer to Fig. 12

5.A 1/2" NPT detergent probe injection point is provided at the rear of the dishwasher.

6.Detergent may be added manually if your dishwasher is not equipped with dispensing equipment. Consult your chemical supplier for recommended amounts.

Refer to Fig. 13

7.A 1/8" NPT rinse aid injection point is provided in the final rinse manifold. Use a liquid rinse aid.

The manifold is located on the top right side of the dishwasher.

8.MH-6L Only

A 1/4" NPT sanitizer injection point is provided in the final rinse manifold.

Models MH-60 and MH-6N do not require sanitizer.

9.Use a sodium hypochlorite (Chlorine) based sanitizer at a minimum concentration of 50PPM in the final rinse.

10.Use chlorine test papers to verify and monitor the 50PPM chlorine level.

WARNING:

!Never premix rinse aid with the sanitizing agent. Mixing may cause hazardous gases to form.

CAUTION:

! Some metal, includng silver, aluminum and pewter are attacked by sodium hypochlorinte (chlorine). Avoid cleaning these metals in a MH-6L.

Figure 12

Detergent Probe Injection Point

1/2" NPT

(Wash Tank Rear)

1/4" NPT Sanitizer

Injection Point

Model MH-6L Only

1/8" NPT Rinse aid Injection Point Models MH-60, MH-6N, MH-6L

Figure 13

Rinse Aid and

Sanitizer Injection Points

(Top of Dishwasher)

15

Page 17
Image 17