Moyer Diebel MH-6LM2 Diagram State End of Cycle Power- Off Door- Closed, MH-60, MH-6N,MH-6L

Models: MH-6LM2 MH-60M2 MH-6NM2

1 68
Download 68 pages 47.65 Kb
Page 65
Image 65
Single PhaseElectricalSchematic

63

 

 

208V-230V/1~ 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAIN POWER SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

OFF

1

 

 

 

 

 

 

 

 

6

OPEN

DOOR

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

POWER

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

 

 

4

LAMP

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOSED

 

 

 

 

 

 

 

 

 

 

 

COMMON

 

 

 

 

 

R2A

R2B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single PhaseElectricalSchematic

 

 

 

 

 

DETERGENT SIGNAL

 

7

R3A

11

11

R2

 

2

MH-60, MH-6N,MH-6L

Figure37

 

2

10

RINSE SIGNAL

10

NO

 

LAMP

 

 

WASH

16

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R3

 

 

 

 

 

 

 

 

 

 

7

 

NO

TIMER

17

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

TMR MTR

 

 

 

 

 

 

 

 

 

34

 

NC

 

R2C

 

 

 

 

 

 

1

2

 

 

7

 

 

 

 

16

18

R1

2

 

 

 

 

 

 

 

 

 

 

 

 

TIMER

R1B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

EXTENDED

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

WASH RH

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

NO

 

HOMING

5

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

 

 

 

 

CYCLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

8

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTACTOR

31

7

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

18

NO

 

RINSE

 

 

RINSE

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

R1C

R1A

 

 

 

 

SWITCH

 

VALVE

 

 

 

 

 

 

 

 

7

 

 

 

 

33

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

NC

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTENDED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WASH LH

 

 

 

 

 

 

 

 

 

THERMOSTAT

 

TANK CONTACTOR

 

 

 

 

 

 

 

A0509520/A

2

HIGH LIMIT

13

 

12

 

 

HC1

19

 

 

 

 

 

 

 

 

 

THERMOSTAT

BOOSTER CONTACTOR (MH-60 Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

HIGH LIMIT

15

 

14

 

 

BC1

19

 

 

 

2

MOTOR

MOTOR

1

OVERLOAD

CONTACTOR

 

20

WASH

22MOTOR

3KW TANK HEAT

HC123

3KW

25

FOR 208V/230V 1 PHASE

9KW BOOSTER HEAT

BC126

9KW

28

FOR 208V/230V 1 PHASE (MH-60 Only)

Customer to supply rated Voltage/Phase/Hz, as specified per order, to disconnect switch. All power supplied to each connection point must comply with all local electric codes.

Diagram State

End of Cycle

Power- Off

Door- Closed

ELECTRICAL SCHEMATICS

Page 65
Image 65
Moyer Diebel MH-6LM2, MH-6NM2, MH-60M2 Diagram State End of Cycle Power- Off Door- Closed, Single PhaseElectricalSchematic