Heater Element Wiring – Booster Tank and Wash Tank Heater Elements

BASIC SERVICE

ELECTRICAL SERVICE (Cont.)

Heater Element Wiring – Booster Tank and Wash Tank Heater Elements

Refer to the illustrations and follow the steps below to properly install terminal jumpers and to make line power connections to a replacement element.

Step 1. Hold the element assembly with the calrod coils facing toward you.

Step 2. Match your element coil to Configuration A, B, C, or D.

Step 3. Rotate your element coils to match the correct configuration.

Step 4. Turn the element over and match your element to the correct terminal configuration. Step 5. Install terminal jumpers according to the illustration for your voltage requirement.

Step 6. Install the element and make your line connections 1L1, 1L2, or 1L3 per the illustration.

Configuration A

Booster tank element View of calrod coils

Terminal Connections View of element

1L1

1L3

1L3

1L3

1L1

 

 

 

 

1L2

 

1L1

1L1

 

 

 

1L2

 

 

 

 

1L2

1L2

 

 

208V/1 Phase

208-240V/3 Phase

480V/3 Phase

208-240V/3 Phase

 

Delta Connection

575V/3 Phase

Wye Connection for

 

 

Delta Connection

380-415V/3 Phase

Configuration B

Booster tank element View of calrod coils

Terminal Connections View of element

1L1

1L1

1L1

 

 

1L2

1L2

 

1L2

 

1L1

1L3

 

1L3

1L3

1L2

 

 

 

208V/1 Phase

208-240V/3 Phase

480V/3 Phase

208-240V/3 Phase

 

Delta Connection

575V/3 Phase

Wye Connection for

 

 

Delta Connection

380-415V/3 Phase

Configuration C

Booster tank element View of calrod coils

Terminal Connections View of element

1L1

 

 

 

 

1L2

1L1

 

1L1

1L3

1L1

1L3

1L3

 

 

 

 

 

 

 

1L2

 

1L2

 

1L2

 

 

208V/1 Phase

208-240V/3 Phase

480V/3 Phase

208-240V/3 Phase

 

Delta Connection

575V/3 Phase

Wye Connection for

 

 

 

Delta Connection

380-415V/3 Phase

Configuration D

Wash tank element View of calrod coils

1L1

1L2

208V/1 Phase

Terminal Connections View of element

1L1

1L1

1L1

 

 

1L2

1L3

1L3

 

1L2

1L2

1L3

208-240V/3 Phase

480V/3 Phase

208-240V/3 Phase

Delta Connection

575V/3 Phase

Wye Connection for

 

Delta Connection

380-415V/3 Phase

Figure 19

Heater Element Wiring

30

Page 32
Image 32