Moyer Diebel MH-6LM5 Water Connections Cont, Drain Connections, Ventilation, Installation

Models: MH-60M5 MH-6LM5 MH-6NM5

1 76
Download 76 pages 62.65 Kb
Page 16
Image 16
Water Connections (Cont.)

INSTALLATION

Water Connections (Cont.)

2.A manual shut-off valve for steam and water (supplied by others) should be installed in the supply line to allow for

servicing of the machine. The shut-off valve should be the same size or larger than the supply line.

3.Install a 3/4" pressure reducing valve (PRV) in the water supply line if flow pressure exceeds 20-22 PSI/138-151.8 kPa.

A PRV is standard equipment on Model MH-60. A PRV is not standard equipment on Models MH-6N, MH-6L.

Drain Connections

Refer to Fig. 9

1. MH series models are GRAVITY DRAIN

 

 

machines equipped with a 1-1/2" O.D.

 

 

hose connection point.

 

 

2. The maximum drain flow rate is

 

 

15 gallons/min-56.8 liters/min.

 

 

3. Drain height for all models must not

11"

[280mm]

Above floor level

exceed 11" (280mm) above floor level.

 

 

4. The drain connection is made to the

 

 

dishwasher from underneath the machine

 

 

through an access hole in the machine base.

 

 

Ventilation

 

 

NOTE:

 

Figure 7

 

Drain Hose Connection

Ventilation must comply with local

 

 

1-1/2" O.D.

sanitary and plumbing codes.

 

(Max flow rate = 15 gal/min-56.8 liters/min)

 

CAUTION:

!Exhaust air should not be vented into a wall, ceiling, or concealed space of a building. Condensation can cause damage.