Fiber Driver® EM316EDFA User Guide
2.1 Features
The EM316EDFA board can run in standalone mode without any input from a management module. The EM316EDFA analog input power determines the output power because the module runs at a fixed gain.
EM316EDFA status is reported through SNMP through a network management module as well as by LEDs on the front panel.
The green “SD” LED on the front panel indicates input greater than the thresholds corresponding to the EDFA module type, as indicated in the table below.
A green LED at front panel (Optical Output) indicates output power greater than
The module temperature is measured from 0 o C to 70o C and reported to management. To protect against excessive heat, the laser shuts down when measured temperature reaches 70o C.
2.1.1
•Input power and output power readings
•Output gain reading
•Case temperature reading
•Amplifier status reading
•Alarm status
ocase temperature o loss of input power o loss of output power
2.1.2EDFA Control Inputs
•Software reset
•Output power mute
2.1.3EDFA Alarm Outputs
•Case temperature
•Loss of input
•Loss of output