MRV Communications EM316EDFA-LPR, EM316EDFA-BR manual Chassis Context, 5.2.4.1“show”

Models: EM316EDFA-LPR EM316EDFA-BR

1 44
Download 44 pages 43.38 Kb
Page 27
Image 27
5.2.4 Chassis Context

Fiber Driver® EM316EDFA User Guide

5.2.4 Chassis Context

Command examples in this section are applied in the chassis-level context. The box below shows the command to navigate to the chassis context from the login context.

fiberdriver# configure terminal fiberdriver(config)# fiberdriver(config)# chassis 1 fiberdriver(chassis/1)#

5.2.4.1show

The following CLI excerpt shows a Fiber Driver chassis system with an EDFA amplifier module and an EM316LNXNM-OT network management (NM) module. Notice that the EDFA module is listed in both slots 1.3 and 1.4.

fiberdriver(chassis/1)# show

Model:

NC316BU-16

 

Name:

NC316BU-1

 

Temp(C):

25

 

 

Temp Min(C):

5

 

 

Temp Limit(C):

55

 

 

PS1: DC Bad

PS2: AC Good

 

Fan1: good

Fan2: good

 

Fan3: good

 

 

Slot Change Traps: on

Module Specific Traps: on

Chassis Traps: on

Port Traps: on

Link Traps: on

Loopback Traps: on

LIN Traps: on

Port Change Traps: on

Port Diags Traps: on

Number Of Slots: 16

1

 

Hardware Revision:

 

Slot Model

 

 

Name

Serial Number

=================== ======================

============================

1.2

EM316LNXNM-OT

EM316LNXNM-OT at 1.2

00:20:1a:02:48:28

1.3

EM316EDFAv

EM316EDFAv at 1.3

N/A

1.4

EM316EDFA

EM316EDFA at 1.4

N/A

1.5

EM316E1MUX4RM

EM316E1MUX4RM at 1.5

12:34:56:78:90:15

1.7EM316EFE1MUXRJv EM316EFE1MUXRJv at 1.7 00:20:1a:77:88:99

1.8EM316EFE1MUXRJ EM316EFE1MUXRJ at 1.8 00:20:1a:77:88:99

fiberdriver(chassis/1)#

Use the command line “?” (help character, shown below) to display command line parameters for the show command.