MRV Communications EM316EDFA-BR 5.2.6.4“port description”, P/N 1294008-001Rev D2, Name EDFA-port1

Models: EM316EDFA-LPR EM316EDFA-BR

1 44
Download 44 pages 43.38 Kb
Page 40
Image 40
5.2.6.4“port description”

Fiber Driver® EM316EDFA User Guide

5.2.6.4port description

As with a module at the slot level, a descriptive name may be applied to each port. An example of the description command at the port level is shown below.

fiberdriver(port/1.3.1)# description EDFA-port1fiberdriver(port/1.3.1)# show

Port: 1.3.1

Name: EDFA-port1

Enable: enable

Link: no Signal

Connector: fo

SC Medium: single Mode

TxPower(dBm):

-15.26

DDiags:

Alarm Temp(C): 23 Supply(V): 3.28

Alarm Cause: TX Loss of Signal Alarm (tx -15.26dBm)

Gain desired(dB): 25

Gain(dB): 24.76

fiberdriver(port/1.3.1)#

P/N 1294008-001 Rev D2