English | Operating Manual for Wood Splitter |
The complete unit with engine
Once per season have a repair shop inspect and service the unit. Also follow the instructions in the engine manual concerning maintenance of the engine.
Shutting down the unit
Caution
Material damage to the unit.
When the engine has cooled down, store the unit in a clean and dry location. If storage is prolonged, always protect the unit, e.g. in winter, from rust. After the season or if the unit is not used for more than a month:
•Clean the unit.
•Protect all metal parts from rust by wiping them with an oiled cloth or spraying them with oil.
•Drain fuel (outdoors only) and disconnect the engine as described in the engine manual.
•Inflate the tyres to the appropriate pressure.
•Store the unit in a clean, dry location.
Warranty
The warranty regulations issued by our company or the importer are valid in all countries. We shall repair any faults on your unit free of charge in accordance with the warranty, provided the fault was due to defective materials or manufacturing.
If claiming under the warranty, please contact your seller or your nearest branch.
Additional information concerning the warranty
The warranty will be deemed null and void with immediate effect if:
•there is too little or incorrect hydraulic fluid in the unit.
•settings of the
Caution
A higher pressure could cause the hoses to burst, the pump to crack and aggressive fluid to escape, resulting in serious injuries.
•The hydraulic pump was disassembled.
•Flexible pump coupling worn due to incorrect or irregular inspection/maintenance.
•No or improper lubrication of the splitting column or unit.
•Incorrectly set splitting wedge/splitting wedge module causes damage.
•The hydraulic system overheats.
•The unit was started at a temperature below
•Unnoticed leaks in the hydraulic system cause damage.
Information about the engine
The engine manufacturer is liable for all
Troubleshooting
Danger
Risk of injury from engine starting unintentionally.
Protect yourself from injury. Before carrying out any work on the unit:
•Switch off the engine.
•Move the operating lever to Neutral.
•Wait until all moving parts have come to a standstill and the engine has cooled down.
•Remove
•Before repairing, adjusting or checking hoses, hose connections, pipelines or other components, depressurise the hydraulics.
Faults which occur while you are operating your unit often have simple causes which you should recognise and which to some extent you can eliminate yourself. If in doubt, please contact your repair shop.
10