INPUT POWER REQUIREMENTS-

At AC Transformer:

110-125 Volts AC Only, 50-60 Hz

At Power Jack On Stick:

12-14Volts AC and DC

POWER CONSUMPTION-

6.2 Watts

CO INTERFACE-

 

Ringer Equivalence Number:

0.5 B

Input Ring Detection:

40-150 Volts AC, 15-68 Hz

DEVICE INTERFACE-

 

Battery:

-48 Volts Nominal DC To All Devices

Off-Hook Detection:

3-80 mA

Ring Generator Frequency:

30 Hz (+/- ..1)Hz Voltage Regulated

 

and Current Limited

Waveform:

True Sinusoidal

Ringing No Load:

Approx. 82.8 Volts RMS AC

Ringing 8000 Ohm Impedance (REN 1.0):

Approx. 8 1.6 Volts RMS AC

Ringing 4000

Ohm Impedance (REN 2.0): Approx. 73.0 Volts RMS AC

Ringing 2667

Ohm Impedance (REN 3.0):

Approx. 64.5 Volts RMS AC

Ringing

2000

Ohm Impedance (REN 4.0):

Approx. 55.0 Volts RMS AC

Ringing

1800

Ohm Impedance (REN 5.0):

Approx. 49.5 Volts RMS AC

29

Page 34
Image 34
Multi-Link Voice/Fax/Modem Call Processor manual Input Power Requirements