Multi-Tech Systems MT5634ZPX-PCI-U manual MultiModemZPX User Guide, B Technical Specification

Models: MT5634ZPX-PCI-U

1 37
Download 37 pages 5.72 Kb
Page 29
Image 29
Frequency Stability

MultiModemZPX User Guide

B Technical Specification

Frequency Stability

±0.01%

 

Receiver Sensitivity

-43 dBm under worst-case conditions

AGC Dynamic Range

43 dB

 

Bus Type

PCI 2.1

 

Connectors

Two RJ-11 phone jacks, one microphone jack, and one speaker jack

Cables

One RJ-11 phone cable

 

 

Note: Any cables connected to the computer should be shielded to

 

reduce interference.

 

Diagnostics

Power-on self-test (POST) and local analog loop

Environmental

Temperature range 0°–50°C (32°–120°F); humidity range 20–90% (non-

 

condensing)

 

Storage Temperature

-10° to +85°C (14°–185°F)

 

Power Requirements

3.3 or 5 volt slot

 

Dimensions

1.8 cm wide × 14.7 cm long ￿× 12.2 cm high (0.7" × 5.8" × 4.8")

Operating Systems

Tested for use with Windows

98, NT, and 2000, and Linux (2.2.x

 

kernal).

 

Limited Warranty

2 years

 