Multi-Tech Systems MT5634ZPX-PCI-V92 manual MultiModemZPX User Guide Index

Models: MT5634ZPX-PCI-V92

1 85
Download 85 pages 32.44 Kb
Page 84
Image 84

MultiModemZPX User Guide

Index

F

fallback 25

Fallback and Fall Forward command 31

fax communications 19–20

faxing from a Windows application 19

FCC regulations 56–57 firmware

upgrading 70–72 version 24

flash 36

flash memory 70

Flash Wizard upgrade utility 71 flow control 27, 30

Flow Control Selection command 27, 30

G

garbage characters 53 Global Wizard 15

Guard Tone Control command 27

H

H.324 video 33 handshake 25 hangup command 24 hangup delay 40

Hook Control command 24

I

inactivity timer 40

Inactivity Timer command 30 Industry Canada regulations 58–60 Information Request command 24 initialization strings 16, 22, 49 installation and setup 4–16 international restrictions 60 Internet addresses 69

L

line connection 6 line feed character 40 Linux 73–75

Load Factory Settings command 16, 27

local analog loopback test 63–64 local digital loopback test 65–66 loopback tests 54, 63–66

lost data 52

M

messages 43–44 microphone 7

MNP 5 data compression 31 MNP error correction 30 Modem on Hold 8, 36, 37 Modem on Hold Enable command 36 Modem on Hold Initiate command

36

Modem on Hold Timer command 37 Modem Reset command 26 Modulation Handshake command 25 Modulation Selection command 34 Monitor Speaker Mode command 25 Multi-Tech Internet sites 69

N

New Zealand regulations 59

O

on-hook/off-hook 24 online command mode 22

P

patch cord for sound card 4, 7 pause time for comma, setting 40 PCM Upstream Ignore command 36 phone connection 6

PhoneTools program 18 Plug and Play 2 programs, communication 16 Protocol Result Code command 30 protocols 52

Pulse Dialing command 25

Q

Quick Connect 37

Quick Connect Control command 37

R

rate, maximum data 41

Read Register Value command 25 reference materials 20 registering your product 67 regulatory compliance 56–60 remote configuration 46–47

escape character 40, 47 escape sequence 39

remote digital loopback test 64–65 remote node operation 19 removing previous modems 14 Repeat command 23

required equipment 4 resetting the modem 26, 27 Result Code Format command 26 Result Code Options command 26 Result Code Selection command 26 result codes 22, 30, 43–44, 50

Result Codes Enable/Disable command 25

Return Online to Data Mode command 25

rings, setting number of 16, 40 ROM checksum 24

S

S-registers40–44 reading 25

S0

16,

40

S1

40

 

S2

40

 

S3

40

 

S4

40

 

S5

40

 

S6

40

 

S7

40

 

S8

40

 

S9

40,

47

S10

 

40

 

S11

40

 

S28

 

40

 

S30

 

40

 

S35

 

40

 

S36

 

40

 

S37

 

41

 

S38

 

41

 

S42

 

42

 

S48

 

42

 

S89

 

42

 

S108

42

S109

42

setting

25

safety

 

4

 

Select Maximum MNP Block Size command 28

Select V.44 Data Compression command 32

serial port 16

servicing your modem 57

Set Register Value command 25 software, communication 16 software installation

in Windows 2000 13

in Windows NT 11

solving problems 49–54 sound card connection 7 Speaker Codec Loopback command

28

Speaker Mode command 25 speakerphone 7, 54 specifications, technical 61–62 speed

maximum 41 serial port 16

speed conversion (data buffer) 27, 29

standby mode delay time 42

79

Page 84
Image 84
Multi-Tech Systems MT5634ZPX-PCI-V92 manual MultiModemZPX User Guide Index

MT5634ZPX-PCI-V92 specifications

The Multi-Tech Systems MT5634ZPX-PCI-V92 is a high-performance V.92 data/fax modem designed to enhance communication capabilities in various applications. This modem is particularly well-suited for commercial and industrial environments where reliable connectivity is crucial.

One of the standout features of the MT5634ZPX-PCI-V92 is its support for the V.92 protocol, which allows for quicker uploads and improved connection speeds compared to earlier standards. It offers download speeds of up to 56 Kbps and upload speeds of up to 48 Kbps, making it an excellent choice for businesses that rely on time-sensitive data transmission. The modem's ability to maintain reliable connections even over noisy telephone lines is a critical aspect of its design, ensuring that users can depend on it for essential communications.

The MT5634ZPX-PCI-V92 also includes advanced error correction and data compression technologies, such as MNP 4 and V.42bis. These technologies work together to ensure data integrity during transfers and to maximize throughput, enabling users to send larger files without compromising quality or speed. Additionally, the modem features a robust fax capability, supporting both analog and digital fax transmissions, which is vital for businesses that frequently deal with document sharing.

A notable characteristic of the MT5634ZPX-PCI-V92 modem is its PCI interface, which allows for easy integration into desktop systems. This plug-and-play capability simplifies installation and setup, making it accessible for users with varying levels of technical expertise. The modem is built on a reliable hardware platform, characterized by its durable components, making it ideal for environments where long-term use is expected.

Moreover, the MT5634ZPX-PCI-V92 comes with comprehensive driver support for various operating systems, including Windows and Linux, ensuring compatibility with a wide range of applications. With its combination of speed, reliability, and ease of use, the Multi-Tech Systems MT5634ZPX-PCI-V92 modem remains a popular option for businesses looking to maintain effective communication channels through dial-up connectivity. Whether for data transmission or faxing, it stands as a solid choice for organizations that require dependable performance in a compact form factor.