Table of Contents
BLW-400SSW — INSTALLATION
Outdoor Installation
Install the welder/AC generator in a location where it will not be exposed to rain or sunshine. Make sure the Welder/AC generator is on secure level ground so it cannot slide or shift around. Also install the welder/AC generator so the exhaust will not be discharged in the direction of nearby homes.
The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation, and will result in short circuits.
Foreign materials such as dust, sand, lint and abrasive materials will cause excessive wear to engine and alternator parts.
CAUTION :
Pay close attention to ventilation when operating the welder/AC generator inside tunnels and caves. The engine exhaust contains noxious elements.
Indoor Installation
Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside.The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure and cause the engine to heat excessively.
Eliminate the danger of deadly carbon monoxide gas. Remember that exhaust fumes from any diesel engine are very poisonous if discharged in a closed room, but harmless if allowed to mix with the outside air. If the welder/AC generator is installed indoors, you must make provisions for venting the engine exhaust to the outside of the building.
CAUTION :
An electric shock may happen when vibrators are used. Pay close attention to handling when operating vibrators and always use rubber boots and gloves to insulate the body from a electrical shock.