Multiquip BLW-400SSW- START-UP Instructions, Automatic Idle Control Switch ‘OFF’ position

Models: BLW-400SSW

1 138
Download 138 pages 39.29 Kb
Page 34
Image 34

Table of Contents

BLW-400SSW— START-UP INSTRUCTIONS

8.Turn the Automatic Idle Control switch to the ‘OFF’ position (Figure 21).

Figure 21. Automatic Idle Control Switch in

‘OFF’ position

9.Insert the key into the starter switch and turn the ‘Run’ position (Figure 22). The oil pressure light will temporarily turn on.

CAUTION:

NEVER turn the key to the “START” position while the engine is running.

12.Switch the engine idle switch to ‘On’ and let engine idle for about 5 minutes. Check the engine for abnormal vibrations or sounds. Turn the engine idle switch to either ‘Off’ or keep in ‘On (Figure 25)’ position for full engine operation.

Figure 22. Starter Switch to ‘RUN’ position

10.Turn the key further to the ‘Heat’ position. The preheat light will go on (Figure 23). Once the light turns off, the engine is ready to operate.

Figure 23. Starter Switch to ‘HEAT’ position

11.Turn the key to the ‘Start’ position (Figure 24) to start the engine, then release the key. Check the engine indicators. If the oil pressure is still on, turn off the engine and check the oil. If the engine does not start within 10 seconds after the key is turned to the ‘Start’ position, release the key, and wait 30 seconds. Repeat procedure above.

Figure 24. Starter Switch to ‘START’ position

Figure 25. Automatic Idle Control Switch in the

’ON’ position

13.Once the engine is running and operating properly, switch the circuit breakers to ‘ON’ position (Figure 26).

Figure 26. Circuit Breaker in ‘ON’ position

14.Check the voltmeter and adjust to proper voltage needed for operation (Figure 27).

Figure 27. AC Voltmeter with load

PAGE 34 — BLW-400SSW- WELDER/AC GENERATOR — PARTS & OPERATION MANUAL — REV. #1 (06/15/01)

Page 34
Image 34
Multiquip operation manual BLW-400SSW- START-UP Instructions, Automatic Idle Control Switch ‘OFF’ position