Table of Contents

BLW-400SSW — SHUTDOWN INSTRUCTIONS

Shutdown

1. Switch the circuit breakers to ‘OFF’ position (Figure 28.

Emergency Shut-Down

To stop during an emergency, turn the key switch to ‘STOP’ position.

Figure 28. Main and receptacle circuit breakers CAUTION :

2.Switch the Idle Control switch to ‘OFF’ position (Figure 29). Let engine run for 5 minutes in idle mode.

Do not shut down the welder/generator set by shutting off the engine except in an emergency.

Figure 29. Idle Control Switch

3. Turn the key switch to ‘STOP’ position (Figure 30).

Figure 30. Key switch set to ‘STOP’ position

4.Remove welding apparatus and output terminal loads from welder/generator set.

5.Turn the fuel cock to closed position.

BLW-400SSW-WELDER/AC GENERATOR— PARTS & OPERATION MANUAL— REV. #1 (06/15/01) — PAGE 35