BLW-400SSW— START-UP INSTRUCTIONS

START UP INSTRUCTIONS

1.Check the oil level before starting the engine. Replenish if necessary. Use specified oil as indicated on page 28, Table 8.

5.Connect the battery cables to the battery with red terminal to positive and black to negative (Figure 18).

DO NOT CONNECT IN REVERSE.

2.Check the coolant level in the radiator and subtank. Always maintain the antifreeze level between the ‘Full’ and ‘Low’ level. Fasten the radiator cap securely.

CAUTION:

The engine's exhaust contains harmful emissions. ALWAYS ventilate the exhaust when operating inside tunnels, excavations or buildings. Direct exhaust away from nearby personnel.

3.Check the fuel level and replenish as necessary. Turn the fuel cock lever to the ‘ON’ position (Figure 16) located inside the engine compartment.

NEGATIVE

POSTIVE

BATTERY

Figure 18. Battery connection

6.Set the “Current Range Selector” switch (Figure 19) to ‘Single’ for one operator or ‘Dual’ for two operators.

Figure 16. Fuel Cock ‘ON’ position

4.Connect load and welding apparatus to output terminals (Figure 17). Check the circuit breakers are in the ‘OFF’ position.

Figure 19. Current Range Selector Switch

7.Always operate the welder with the doors closed (Figure 20). Operation with the doors open may cause insufficient cooling to the unit, and may damage the unit.

Figure 20. Doors in closed position

Figure 17. Terminal Connection and Circuit

Breakers

BLW-400SSW-WELDER/AC GENERATOR— PARTS & OPERATION MANUAL— REV. #1 (06/15/01) — PAGE 33