DCA-180SSV — GENERATOR OUTPUTS
Generator OutputVoltages
A wide range of voltages are available to supply voltage for many different applications. Voltages are selected by apply- ing jumpers (6) to the voltage
Voltage Change-Over Board
The voltage
Generator Amperage
Tables 8 and 9 describe the generator’s current output capa- bility for both
Table 8. Generator Ampere Ratings ⎯ 1∅
kW | 120V | 240V |
|
|
|
18 | 150 | 75 |
|
|
|
38 | 316 | 158 |
|
|
|
58 | 483 | 267 |
|
|
|
78 | 650 | 236 |
|
|
|
98 | 817 | 492 |
|
|
|
118 | 983 | 319 |
|
|
|
138 | 1,150 | 575 |
|
|
|
158 (Max) | 1,317 | 658 |
|
|
|
Figure 14. Voltage Change-Over Board
CAUTION - CHANGINGVOLTAGES
NEVER attempt to place jumper plates on the voltage
Table 7. Voltages Available
Three Phase | 208V | 220V | 240V | 416V | 440V | 480V | |
(Switchable) | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
Single Phase | 120V | 127V | 139V | 240V | 254V | 277V | |
(Switchable) | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
Table 9. Generator Ampere Ratings ⎯ 3∅
KVA | 240V | 480V |
|
|
|
20 | 48 | 24 |
|
|
|
40 | 96 | 48 |
|
|
|
60 | 144 | 72 |
|
|
|
80 | 192 | 96 |
|
|
|
100 | 241 | 120 |
|
|
|
120 | 289 | 144 |
|
|
|
140 | 337 | 168 |
|
|
|
160 | 384 | 192 |
|
|
|
180 (Max) | 433 | 216 |
|
|
|