B a t t e r y

CAUTION:

Never over fill the battery with water above the upper limit.

The battery contains acids that can cause injury to the eyes and skin.To avoid eye irritation, always wear safety glasses. Use well insulated gloves when picking up the battery. Use the following guidelines when handling the battery:

1.DO NOT drop the battery. There is the possibility of risk that the battery may explode.

2.DO NOT expose the battery to open flames, sparks, cigarettes etc. The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

3.Always keep the battery charged. If the battery is not charged a buildup of combustible gas will occur.

4.Always keep battery charging and booster cables in good working condition. Repair or replace all worn cables.

5.Always recharge the battery in an open air environment, to avoid risk of a dangerous concentration of combustible gases.

6.In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

7.In case the battery liquid (dilute sulfuric acid) comes in contact with your eyes, rinse eyes immediately with plenty of water, then contact the nearest doctor or hospital, and seek medical attention.

Table of Contents

RULES FOR SAFE OPERATION

!NEVER Run engine without air filter. Severe engine damage may occur.

!Always service air cleaner frequently to prevent carburetor malfunction.

!Always disconnect the battery before performing service on the generator.

!Always be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

!Always store equipment properly when not in use. Equipment should be stored in a clean, dry location out of the reach of children.

!DO NOT leave the generator running in the manual mode unattended.

!DO NOT allow unauthorized people to operate this equipment.

!Always read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

!Refer to the Komatsu Engine Owner's Manualfor engine technical questions or information.

Loading and Unloading (Crane)

!Before lifting, make sure the generator's lifting hook is secure and that there is no apparent damage to the generator itself (loose screws, nuts and bolts). If any part is loose or damaged, please take corrective action before lifting.

!Always drain fuel prior to lifting.

!Always make sure crane or lifting device has been properly secured to the hook of guard frame on generator.

!NEVER lift the machine while the engine is running.

!Use adequate lifting cable (wire or rope) of sufficient strength.

!When lifting the generator, always use the balanced center-point suspension hook and lift straight upwards.

!NEVER allow any person or animal to stand underneath the machine while lifting.

!When loading the generator on a truck, be sure to use the front and back frame bars as a means to secure the generator during transport.

PAGE 8 — DCA-220SSK — PARTS AND OPERATION MANUAL (STD) — REV. #3 (06/05/01)

Page 8
Image 8
Multiquip DCA-220SSK operation manual T t e r y, Loading and Unloading Crane

DCA-220SSK specifications

The Multiquip DCA-220SSK is a robust and versatile generator designed to meet the diverse demands of construction sites, rental facilities, and emergency backup needs. This generator stands out with its ability to deliver reliable power in a compact and easy-to-transport package.

At the heart of the DCA-220SSK is a powerful water-cooled, 4-cylinder diesel engine that provides a rated output of 220 kVA. This engine is coupled with a heavy-duty alternator that ensures an efficient and stable power supply, making it suitable for a wide range of applications. The generator features a sound-attenuated enclosure, designed to minimize noise levels and enhance mobility. This encasement not only protects the inner components from harsh environmental conditions but also complies with strict noise regulations, making it a great choice for urban job sites.

One of the key features of the DCA-220SSK is its advanced digital control panel, which offers intuitive monitoring and management of the generator's operation. This panel allows users to easily track essential performance metrics such as voltage, frequency, and hour count, ensuring optimal functionality. Furthermore, it is equipped with several safety features, including low oil pressure and high temperature shutdowns, which protect the unit from damage and extend its lifecycle.

In terms of fuel efficiency, the DCA-220SSK is designed to operate at a low fuel consumption rate, making it cost-effective for long-term use. Additionally, its large fuel tank provides extended runtime, enhancing productivity by reducing the frequency of refueling.

The generator's compact design is complemented by heavy-duty wheels and lifting points, facilitating ease of transportation and deployment in various job settings. This rugged design is ideally suited for construction, industrial use, and other commercial applications, where reliability and performance are paramount.

Ultimately, the Multiquip DCA-220SSK delivers high-quality power with its innovative technology and features that cater to the needs of end users seeking durability, efficiency, and reliability in their power solutions. Whether for temporary power at a construction site or as a dependable backup during emergencies, this generator is a commendable choice in the competitive landscape of commercial power equipment.