Table of Contents

DCA-220SSK — LOAD APPLICATION

Single Phase Load

Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage and frequency requirements are satisfactorily supplied by the generator for operating the equipment.

Generally, the wattage listed on the nameplate of the equipment is its rated output. Equipment may require 130— 150% more wattage than the rating on the nameplate, as the wattage is influenced by the efficiency, power factor and starting system of the equipment.

NOTE

If wattage is not given on the equipment's name plate, approximate wattage may be determined by multiplying nameplate voltage by the nameplate amperage.

WATTS = VOLTAGE x AMPERAGE

The power factor of this generator is 1.0. See Table 14. below when connecting loads.

Table 14. Power Factor By Load

Type Of Load

Power Factor

 

 

Single-phase induction motors

0.4 - 0.75

 

 

Electric heaters, incandescent

1.0

lamps

 

 

 

Fluorescent lamps, mercury lamps

0.4 - 0.9

 

 

Electronic devices, communication

1.0

equipment

 

 

 

Three Phase Load

When calculating the power requirements for 3-phase power use the following equation:

CAUTION:

Motors and motor-driven equipment draw much greater current for starting than during operation.

An inadequate size connecting cable which cannot carry the required load can cause a voltage drop which can burn out the appliance or tool and overheat the cable.

"When connecting a resistance load such as an incandescent lamp or electric heater, a capacity of up to the generating set’s rated output (kW) can be used.

"When connecting a fluorescent or mercury lamp, a capacity of up to the generating set’s rated output (kW) multiplied by 0.6 can be used.

"When connecting an electric drill or other power tools, pay close attention to the required starting current capacity.

When connecting ordinary power tools, a capacity of up to the generating set’s rated output (kW) multiplied by 0.8 can be used.

CAUTION:

Before connecting this generator to any building’s electrical system, a licensed electrician must install an isolation (transfer) switch. Serious injury or death may result without this transfer switch.

N O T E

If output (kVA) is not given on the equipment nameplate, approximate output may be determined by multiplying

voltage by amperage by .

PAGE 48 — DCA-220SSK — PARTS AND OPERATION MANUAL (STD) — REV. #3 (06/05/01)

Page 48
Image 48
Multiquip operation manual DCA-220SSK Load Application, Single Phase Load, Three Phase Load

DCA-220SSK specifications

The Multiquip DCA-220SSK is a robust and versatile generator designed to meet the diverse demands of construction sites, rental facilities, and emergency backup needs. This generator stands out with its ability to deliver reliable power in a compact and easy-to-transport package.

At the heart of the DCA-220SSK is a powerful water-cooled, 4-cylinder diesel engine that provides a rated output of 220 kVA. This engine is coupled with a heavy-duty alternator that ensures an efficient and stable power supply, making it suitable for a wide range of applications. The generator features a sound-attenuated enclosure, designed to minimize noise levels and enhance mobility. This encasement not only protects the inner components from harsh environmental conditions but also complies with strict noise regulations, making it a great choice for urban job sites.

One of the key features of the DCA-220SSK is its advanced digital control panel, which offers intuitive monitoring and management of the generator's operation. This panel allows users to easily track essential performance metrics such as voltage, frequency, and hour count, ensuring optimal functionality. Furthermore, it is equipped with several safety features, including low oil pressure and high temperature shutdowns, which protect the unit from damage and extend its lifecycle.

In terms of fuel efficiency, the DCA-220SSK is designed to operate at a low fuel consumption rate, making it cost-effective for long-term use. Additionally, its large fuel tank provides extended runtime, enhancing productivity by reducing the frequency of refueling.

The generator's compact design is complemented by heavy-duty wheels and lifting points, facilitating ease of transportation and deployment in various job settings. This rugged design is ideally suited for construction, industrial use, and other commercial applications, where reliability and performance are paramount.

Ultimately, the Multiquip DCA-220SSK delivers high-quality power with its innovative technology and features that cater to the needs of end users seeking durability, efficiency, and reliability in their power solutions. Whether for temporary power at a construction site or as a dependable backup during emergencies, this generator is a commendable choice in the competitive landscape of commercial power equipment.