Table of Contents

DCA-220SSK — ENGINE OPERATING PANEL

The definitions below describe the controls and functions of the DCA-220SSK " Engine Operating Panel "(Figure 11).

1.Engine Speed Switch – This switch controls the constant speed of the engine.

2.Caution Lamp - This light indicates the generator is running.

3.Throttle Handle - This handle controls the speed of the engine (low or high).

4.Tachometer – Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.

5.Engine Warning Display Module – This module display’s the following engine failures:

A.Overheat Lamp – This lamp goes ON when the cooling water temperature rises abnormally. If the lamp goes ON during normal operation of the generator, the emergency shutdown device will stop the engine automatically.

B.Low Oil Pressure Lamp – During normal operation of the generator this lamp should remain OFF. When the Auto-OFF/Reset- Manual switch is set to the “Manual” position to start the engine, the lamp will be lit. After the oil pressure rises after start-up the lamp will go OFF. If this lamp is ever lit (ON) during normal operation of the generator, the emergency shutdown device will stop the engine automatically.

C.Low Fuel Level Lamp – When this lamp is ON, it is time to stop the engine and add fuel. Remember to let the engine cool before adding fuel.

D.Low Battery Fluid Lamp – This lamp goes ON when the battery fluid is low. If this lamp goes ON during normal operation of the generator, stop the engine and fill the battery with distilled water to the specified level.

E.Clogged Air Filter Lamp – This lamp goes ON when the air filter is clogged. If this lamp goes ON during normal operation of the generator, stop the engine and replace the air filter.

6.Oil Pressure Gauge – During normal operation this gauge be should read in the “GREEN” zone. When starting the generator the oil pressure mar read a little bit higher, but after the engine warms up the oil pressure should return to the green zone.

7.WaterTemperature Gauge – During normal operation this gauge be should read in the “GREEN” zone.

8.Charging Ammeter Gauge – Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.

9.Pre-Heat Lamp – Indicates that the glow plugs of the diesel engine are hot and the engine is ready to be started.

10.Emergency Stop Button – Push this button inward to stop the engine in the event of an emergency. DO NOT use this button as a means of stopping the engine.

11.Starter Switch - This turns the generator on or off. (The generator is not equipped with this feature if has MPEC (see Control Panel).

12.Battery Switch – This switch should be set to the ON position during normal operation. When the engine has been stop, place this switch in the OFF position. DO NOT turn this switch during normal operation, it could cause damage to the electrical equipment.

13.Air Cleaner Indicator - Indicates the air filter needs replacement.

DCA-220SSK — PARTS AND OPERATION MANUAL (STD)— REV. #3 (06/05/01) — PAGE 33

Page 33
Image 33
Multiquip operation manual DCA-220SSK Engine Operating Panel

DCA-220SSK specifications

The Multiquip DCA-220SSK is a robust and versatile generator designed to meet the diverse demands of construction sites, rental facilities, and emergency backup needs. This generator stands out with its ability to deliver reliable power in a compact and easy-to-transport package.

At the heart of the DCA-220SSK is a powerful water-cooled, 4-cylinder diesel engine that provides a rated output of 220 kVA. This engine is coupled with a heavy-duty alternator that ensures an efficient and stable power supply, making it suitable for a wide range of applications. The generator features a sound-attenuated enclosure, designed to minimize noise levels and enhance mobility. This encasement not only protects the inner components from harsh environmental conditions but also complies with strict noise regulations, making it a great choice for urban job sites.

One of the key features of the DCA-220SSK is its advanced digital control panel, which offers intuitive monitoring and management of the generator's operation. This panel allows users to easily track essential performance metrics such as voltage, frequency, and hour count, ensuring optimal functionality. Furthermore, it is equipped with several safety features, including low oil pressure and high temperature shutdowns, which protect the unit from damage and extend its lifecycle.

In terms of fuel efficiency, the DCA-220SSK is designed to operate at a low fuel consumption rate, making it cost-effective for long-term use. Additionally, its large fuel tank provides extended runtime, enhancing productivity by reducing the frequency of refueling.

The generator's compact design is complemented by heavy-duty wheels and lifting points, facilitating ease of transportation and deployment in various job settings. This rugged design is ideally suited for construction, industrial use, and other commercial applications, where reliability and performance are paramount.

Ultimately, the Multiquip DCA-220SSK delivers high-quality power with its innovative technology and features that cater to the needs of end users seeking durability, efficiency, and reliability in their power solutions. Whether for temporary power at a construction site or as a dependable backup during emergencies, this generator is a commendable choice in the competitive landscape of commercial power equipment.