FastStor Error Messages

If, during operation of your FastStor an error occurs, the FastStor will halt the current operation and an error message will be displayed on the LCD. In all cases, after removing the cause of the problem, cycle power on your FastStor and try the last operation again.

Error Message Listing

A description of each of the FastStor error messages is provided in the following table:

Error Name

Description

Error Name

Description

 

 

 

 

SERIAL RCV

Interprocessor communication error

PCKR EMPTY *

The media picker was empty

 

 

 

 

SRC EMPTY *

The source location is empty

SLOT FULL *

There was medium in slot

 

 

 

 

dEST FULL *

The destination location is full

NVM SELECT

NVRAM selection failure

 

 

 

 

CPU RX ERR

The motion CPU is not ready to receive

NVM WRITE

NVRAM write failure

 

 

 

 

CPU TX ERR

The motion CPU is not ready to transmit

dRIVE EJCT

Drive failed to eject medium

 

 

 

 

SLOT EMPTY

No slot beam was detected

dRIVE LOAd

Unable to load medium into drive

 

 

 

 

PWR SWITCH

The front power switch was pressed

dRIVE UNLd *

Drive not logically unloaded

 

 

 

 

HALT

The motion CPU has been halted by a low ACT line

dRIVE HNdL

Drive ‘Operate Handle’ timeout

 

 

 

 

CAM LIMIT

A cam limit has been reached w/o tripping a sensor

dRIVE BUSY

Drive busy, cannot unload tape

 

 

 

 

JAW SENSOR

A jaw sensor was tripped

dRIVE PGRM

Attempt to set drive parameters failed

 

 

 

 

INV MOV OP *

An invalid move operation occurred

dRIVE dOOR

Drive door stepper motor limit

 

 

 

 

REAR TAPE

A rear tape sensor was not tripped

dRIVE FULL *

The drive was full

 

 

 

 

FRONT TAPE

A front tape sensor was not tripped

CT FAILED

Cleaning tape failed to clean drive

 

 

 

 

REAR SLOT

A rear slot sensor was not tripped

dRIVE POST

Drive failed its POST

 

 

 

 

FRONT SLOT

A front slot sensor was not tripped

RObOT POST

Robotics failed its POST

 

 

 

 

PCKR FULL *

The media picker was full

 

 

 

 

 

 

* These errors will not appear on the LCD if the error occurred during SCSI interaction.

Note

During the FastStor POST, if the CT FAILEd, dRIVE bUSY, dRIVE dOOR, dRIVE EJCT, dRIVE HNdL, dRIVE LOAd, dRIVE PGRM, or dRIVE UNLd error occurs, dRIVE POST will appear on the Operators Panel LCD. All other errors occurring during FastStor POST will result in RObOT POST being displayed.

48Troubleshooting and Diagnostics

Page 64
Image 64
ADIC FastStor Mass Storage Device manual FastStor Error Messages, Error Message Listing