40 Troubleshooting and Diagnostics
After entering the dIAG MENU, press the MODE button until CYCLE TEST appears on the LCD:
Cycle TEST
1 2 3 4 5 6 7
Press SELECT to initiate the CYCLE TEST function. The following will appear on the LCD:
CycleS
1 2 3 4 5 6 7
Press the NEXT button to cycle through the number of desired cycles.
Press SELECT when the desired number of cycle tests is displayed.
Notes
If you want the FastStor to execute CYCLE TEST continually, press PREVIOUS until CYCLES 0 is displayed.
Press SELECT to execute continuous CYCLE TEST.
To terminate contimuous CYCLE TEST, press and hold MODE for approximately 10 seconds.
During CYCLE TEST execution, FastStor moves the cartridges from one slot to another, and places each cartridge into the drive
When CYCLE TEST is completed, your FastStor will return to LdR REAdY.

CLEAN DRIVE

The following procedure is to be used only if your application does not support an auto clean cycle and you choose not to use
the FastStor AUTOCLEAN feature.
After entering the dIAG MENU, press the MODE button until CLEAN dRIVE appears on the LCD:
CLEAN RV
2 3 4 5 6 7