DCA-300SSK SERIES — MAINTENANCE

General Inspection

Prior to each use, the generating set should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel or oil leaks.

Air Cleaner

Every 50 hours: If dust indicator is RED, clean the air cleaner element.

Outer Element:

1.Loosen wing bolt, remove dust cup, then remove wing nut and take out element.

2.Clean the inside of the body and cover using a damp cloth.

3.Blow dry with compressed air (0.69Mpa {7kgf.cm2, 99.4 PSI} maximum) against the side of the element along the pleats. Then blow dry against outside along the pleats, then against inside again.

4.Remove one seal each time the element is cleaned.

5.Replace the outer element after cleaning it 6 times or after one year. Replace the outer element if indicator is red even after cleaning it.

6.Check the inner cylinder element clamping nut for looseness, and retighten if necessary.

7.If seal washer is damaged or the threads of wing nut are damaged, replace.

8.Remove evacuator valve and clean it with compressed air. Reinstall.

Inner element (if equipped)

1.Remove the cover and outer element, then remove the inner element.

2.Cover the air connector opening (outer side) with clean cloth or cloth tape.

3.Clean the inside of the body. Remove air connector opening protection.

4.Install a new inner cylinder element to the cylinder and tighten the nut.

5.Install element.

6.After replacing the element, press the button of the dust indicator to return the red piston to its original position.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations). Always pour through the mesh filter.

Removing Water from the Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally remove the drain cock and drain the contents. During cold weather, the greater the empty volume inside the tank, the easier it is for water to condense. This can be reduced by always keeping the tank as full as possible.

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure.

To restart after running out of fuel, turn the key switch to the “START” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.

Service Daily

If engine is operating in very dusty and dry grass conditions, a clogged air cleaner will result in high fuel consumption, loss of power and excessive carbon buildup in the combustion chamber.

Cleaning the Fuel Strainer

Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in diesel. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 29.

Check Electric Heater (If equipped)

Before starting in cold weather (once a year), please contact your Komatsu distributor for inspection. Remove electric heater from the engine intake manifold and check for disconnections or dirt. When checking or installing the electric heater, replace the gasket with a new part.

DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD)— REV. #4 (03/27/06) — PAGE 45

Page 45
Image 45
Multiquip DCA-300SSK General Inspection, Air Cleaner, Outer Element, Inner element if equipped, Fuel Addition, Air Removal

DCA-300SSK specifications

The Multiquip DCA-300SSK is a powerful and versatile silent diesel generator designed to meet the demands of various applications, from construction sites to outdoor events. With its robust features and advanced technologies, this generator ensures reliability and efficiency in power generation.

One of the standout features of the DCA-300SSK is its impressive power output capability. With a maximum capacity of 300 kVA, it can support multiple tools and equipment simultaneously, making it ideal for construction projects, emergency backup, and rental services. Its diesel engine, known for its durability, provides a consistent power supply while being fuel-efficient.

The DCA-300SSK is also notable for its sound attenuation technology. Equipped with a specialized enclosure, this generator operates at a reduced noise level, making it suitable for noise-sensitive environments. This feature is particularly beneficial in urban settings or during nighttime operations where excessive noise could be disruptive.

Safety is paramount in any power generation equipment, and the DCA-300SSK integrates various safety features to protect both the operator and the machine. It includes an automatic shutdown function for low oil pressure and high coolant temperature, ensuring the engine is safeguarded against potential damage. Additionally, the generator is equipped with circuit breakers to prevent electrical overloads, enhancing overall operational safety.

Portability is another key characteristic of the DCA-300SSK. The unit is mounted on a heavy-duty frame with integrated lifting and transport provisions, enabling easy relocation. This feature is particularly advantageous for contractors who need to move the generator frequently from one job site to another.

The generator also features a user-friendly control panel, providing operators with easy access to monitoring essential parameters such as voltage, frequency, and operational hours. This design ensures that users can maintain optimal performance while minimizing downtime.

With its reliable performance, innovative technology, and user-centric design, the Multiquip DCA-300SSK stands out as a top choice for anyone seeking a dependable diesel generator solution. Whether for emergency backup power or heavy-duty usage, the DCA-300SSK delivers efficiency and peace of mind in power generation.