DCA-300SSK SERIES — SAFETY MESSAGE ALERT SYMBOLS

FOR YOUR SAFETY AND THE SAFETY OF OTHERS!

HAZARD SYMBOLS

Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.

This Owner's Manual has been

developed to provide complete

NOTE instructions for the safe and efficient operation of the MQ Power Model DCA-400SSVU

Whisperwatt™ Generator.

Before using this generator, ensure that the operating individual has read and understands all instructions in this manual.

SAFETY MESSAGE ALERT SYMBOLS

The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION.

DANGER

You WILL be KILLED or SERIOUSLY injured if you do not follow directions.

WARNING

You COULD be KILLED or SERIOUSLY injured if you do not follow directions.

CAUTION

You CAN be injured if you do not follow directions

Potential hazards associated with the operation of this equipment will be referenced with "Hazard Symbols" which appear throughout this manual, and will be referenced in conjunction with Safety "Message Alert Symbols".

WARNING - LETHAL EXHAUST GASES

Gasoline engine exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause DEATH if inhaled. NEVER operate this

equipment in a confined area or enclosed structure that does not provide ample free flow air.

WARNING - EXPLOSIVE FUEL

Gasoline is extremely flammable, and its vapors can cause an explosion if ignited. DO NOT start the engine near spilled fuel or combustible fluids. DO NOT fill the fuel tank while the engine is running or hot.

DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system. Store fuel in approved containers, in well-ventilated areas and away from sparks and flames. NEVER use fuel as a cleaning agent.

WARNING - BURN HAZARDS

Engine components can generate extreme heat.To prevent burns, DO NOT touch these areas while the engine is running or immediately after operations. NEVER operate the engine with heat shields or heat guards removed.

DANGER - ELECTROCUTION HAZARDS

During operation of this generator, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

PAGE 8 — DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/27/06)

Page 8
Image 8
Multiquip manual DCA-300SSK Series Safety Message Alert Symbols, Hazard Symbols

DCA-300SSK specifications

The Multiquip DCA-300SSK is a powerful and versatile silent diesel generator designed to meet the demands of various applications, from construction sites to outdoor events. With its robust features and advanced technologies, this generator ensures reliability and efficiency in power generation.

One of the standout features of the DCA-300SSK is its impressive power output capability. With a maximum capacity of 300 kVA, it can support multiple tools and equipment simultaneously, making it ideal for construction projects, emergency backup, and rental services. Its diesel engine, known for its durability, provides a consistent power supply while being fuel-efficient.

The DCA-300SSK is also notable for its sound attenuation technology. Equipped with a specialized enclosure, this generator operates at a reduced noise level, making it suitable for noise-sensitive environments. This feature is particularly beneficial in urban settings or during nighttime operations where excessive noise could be disruptive.

Safety is paramount in any power generation equipment, and the DCA-300SSK integrates various safety features to protect both the operator and the machine. It includes an automatic shutdown function for low oil pressure and high coolant temperature, ensuring the engine is safeguarded against potential damage. Additionally, the generator is equipped with circuit breakers to prevent electrical overloads, enhancing overall operational safety.

Portability is another key characteristic of the DCA-300SSK. The unit is mounted on a heavy-duty frame with integrated lifting and transport provisions, enabling easy relocation. This feature is particularly advantageous for contractors who need to move the generator frequently from one job site to another.

The generator also features a user-friendly control panel, providing operators with easy access to monitoring essential parameters such as voltage, frequency, and operational hours. This design ensures that users can maintain optimal performance while minimizing downtime.

With its reliable performance, innovative technology, and user-centric design, the Multiquip DCA-300SSK stands out as a top choice for anyone seeking a dependable diesel generator solution. Whether for emergency backup power or heavy-duty usage, the DCA-300SSK delivers efficiency and peace of mind in power generation.