Coolant (Antifreeze/Summer Coolant/Water)

ISUZU recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the ISUZU Engine Owner's Manual for further details.

DCA-56SPX — SETUP

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

WARNING - BURN HAZARDS

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled.The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 9 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the ISUZU Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the ISUZU

Engine Owner's Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 26) when depressed with the thumb as shown below.

Table 9. Coolant Capacity

Engine and Radiator

3.43 Gal. (13 liters)

 

 

Reserve Tank

2 Quarts (1.9 liters)

 

 

Operation FreezingWeather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 10) has been added.

Table 10. Anti-Freeze

Operating Temperatures

Vol %

Freezing Point

 

 

Anti-Freeze

 

 

°C

°F

 

 

 

 

50

-37

-34

 

 

 

Figure 26. Fan Belt Tension

CAUTION - ROTATING PARTS

NEVER place hands near the belts or fan while the generator set is running.

NOTE

When the antifreeze is mixed with

water, the antifreeze mixing ratio

 

 

must be less than 50%.

DCA-56SPX— OPERATION AND PARTS MANUAL — REV. #1 (04/14/10) — PAGE 33

Page 33
Image 33
Multiquip DCA-56SPX Coolant Antifreeze/Summer Coolant/Water, Cleaning the Radiator, Air Cleaner Fan Belt Tension

DCA-56SPX specifications

The Multiquip DCA-56SPX is a versatile and robust portable generator designed for a variety of applications, from construction sites to outdoor events. This generator combines performance, reliability, and user-friendly features, making it an essential tool for both professionals and DIY enthusiasts.

At the heart of the DCA-56SPX is a powerful Yanmar diesel engine that delivers a maximum output of 56 kVA. This generator is engineered for high efficiency and longevity, with a robust design that allows it to run for extended periods under heavy loads. The engine also adheres to stringent emissions standards, ensuring environmentally friendly operation without compromising performance.

One of the standout features of the DCA-56SPX is its advanced digital control panel. This user-friendly interface provides real-time monitoring of key parameters, such as voltage, frequency, and total runtime. It simplifies the operation and maintenance of the generator, enabling users to make informed decisions about power management. The control panel also includes safety features, such as low oil pressure and high-temperature shutdowns, to protect the engine from potential damage.

The DCA-56SPX is also equipped with a sound-attenuated enclosure, significantly reducing noise levels during operation. This feature is particularly beneficial in urban environments or areas where quiet operation is a priority. Moreover, the durable, weather-resistant design of the generator ensures reliable performance in various outdoor conditions.

Portability is another key characteristic of the DCA-56SPX. The generator is fitted with heavy-duty wheels and a sturdy frame that allows for easy transport across job sites. In addition to its mobility, the unit is designed for easy access to service points, facilitating quick maintenance and minimizing downtime.

Flexibility is further enhanced by the generator's multiple output options, including 120/240V single phase and 120/208V three-phase configurations. This versatility allows users to connect various tools and equipment, making the DCA-56SPX suitable for numerous applications, from powering construction machinery to providing backup power during outages.

Overall, the Multiquip DCA-56SPX stands out due to its robust design, efficient engine, advanced control technologies, and user-oriented features. It is an excellent investment for those seeking a reliable power source that can handle demanding tasks while ensuring safety, portability, and efficiency. Whether for construction, event planning, or emergency situations, the DCA-56SPX delivers dependable performance to meet diverse power needs.