DCA-56SPX — MAINTENANCE

TABLE 11. INSPECTION/MAINTENANCE

 

10 Hrs

250 Hrs

500 Hrs

 

1000 Hrs

 

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

 

X

 

 

 

 

 

 

 

 

 

 

 

ENGINE

Clean Air Filter

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Fuel Filter/Water Seperator Bowl

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Replace Air Filter Element * 3

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check all Hoses and Clamps * 4

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

 

 

X

 

 

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance Over 3M ohms

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Replace engine oil anf filter at 100 hours, first time only.

 

 

 

 

 

*2

Add "Supplemental Coolant Addatives (SCA'S)" to recharge the engine coolant.

 

 

 

 

*3 Replace primary air filter element when restriction indicator shows a vaccum of 625 mm (25 in. H20).

 

 

*4

If blowby hose needs to be replaced, ensure that the slope of the bloby hose is at least a 1/2 inch per foot, with

 

 

no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks.Use Table 11 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)

Air Cleaner

Every 250 hours: Remove air cleaner element and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Service Daily

If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result. This can lead to

aloss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations).

Removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally inspect the fuel tank for water contamination and drain the contents if required.

During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.

DCA-56SPX— OPERATION AND PARTS MANUAL — REV. #1 (04/14/10) — PAGE 39

Page 39
Image 39
Multiquip operation manual DCA-56SPX Maintenance

DCA-56SPX specifications

The Multiquip DCA-56SPX is a versatile and robust portable generator designed for a variety of applications, from construction sites to outdoor events. This generator combines performance, reliability, and user-friendly features, making it an essential tool for both professionals and DIY enthusiasts.

At the heart of the DCA-56SPX is a powerful Yanmar diesel engine that delivers a maximum output of 56 kVA. This generator is engineered for high efficiency and longevity, with a robust design that allows it to run for extended periods under heavy loads. The engine also adheres to stringent emissions standards, ensuring environmentally friendly operation without compromising performance.

One of the standout features of the DCA-56SPX is its advanced digital control panel. This user-friendly interface provides real-time monitoring of key parameters, such as voltage, frequency, and total runtime. It simplifies the operation and maintenance of the generator, enabling users to make informed decisions about power management. The control panel also includes safety features, such as low oil pressure and high-temperature shutdowns, to protect the engine from potential damage.

The DCA-56SPX is also equipped with a sound-attenuated enclosure, significantly reducing noise levels during operation. This feature is particularly beneficial in urban environments or areas where quiet operation is a priority. Moreover, the durable, weather-resistant design of the generator ensures reliable performance in various outdoor conditions.

Portability is another key characteristic of the DCA-56SPX. The generator is fitted with heavy-duty wheels and a sturdy frame that allows for easy transport across job sites. In addition to its mobility, the unit is designed for easy access to service points, facilitating quick maintenance and minimizing downtime.

Flexibility is further enhanced by the generator's multiple output options, including 120/240V single phase and 120/208V three-phase configurations. This versatility allows users to connect various tools and equipment, making the DCA-56SPX suitable for numerous applications, from powering construction machinery to providing backup power during outages.

Overall, the Multiquip DCA-56SPX stands out due to its robust design, efficient engine, advanced control technologies, and user-oriented features. It is an excellent investment for those seeking a reliable power source that can handle demanding tasks while ensuring safety, portability, and efficiency. Whether for construction, event planning, or emergency situations, the DCA-56SPX delivers dependable performance to meet diverse power needs.