Battery

This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary.

DO NOT over fill. Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Always keep the terminals firmly tightened. Coating the terminals with an approved battery terminal treatment compound. Replace battery with only recommended type battery. The battery type used in this generator is BCI Group 27.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Before charging the battery with an external electric source, be sure to disconnect the battery cables.

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 27) are properly connected to the battery terminals as shown below.The Red Cable is connected to the positive terminal of the battery, and the Black Cable is connected to the negative terminal of the battery.

CAUTION - BATTERY SERVICING SAFETY

ALWAYS disconnect the negative terminal FIRST and reconnect negative terminal LAST.

Figure 27. Battery Connections

DCA-56SPX — SETUP

When connecting battery do the following:

1.NEVER connect the battery cables to the battery terminals when the MPEC Control Switch is in either the MANUAL position.ALWAYS make sure that the MPEC Control Switch is in the OFF/RESET position when connecting the battery.

2.Place a small amount of battery terminal treatment compound around both battery terminals.This will ensure a good connection and will help prevent corrosion around the battery terminals.

If the battery cable is connected

NOTE incorrectly, electrical damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

CAUTION - BATTERY SERVICING SAFETY

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Alternator

The polarity of the alternator is negative grounding type. When an inverted circuit connection takes place, the circuit will be in short circuit instantaneously resulting the alternator failure.

DO NOT put water directly on the alternator. Entry of water into the alternator can cause corrision and damage the alternator.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.

PAGE 34 — DCA-56SPX— OPERATION AND PARTS MANUAL — REV. #1 (04/22/10)

Page 34
Image 34
Multiquip DCA-56SPX operation manual Battery Cable Installation, Alternator, Wiring, Piping and Hose Connection

DCA-56SPX specifications

The Multiquip DCA-56SPX is a versatile and robust portable generator designed for a variety of applications, from construction sites to outdoor events. This generator combines performance, reliability, and user-friendly features, making it an essential tool for both professionals and DIY enthusiasts.

At the heart of the DCA-56SPX is a powerful Yanmar diesel engine that delivers a maximum output of 56 kVA. This generator is engineered for high efficiency and longevity, with a robust design that allows it to run for extended periods under heavy loads. The engine also adheres to stringent emissions standards, ensuring environmentally friendly operation without compromising performance.

One of the standout features of the DCA-56SPX is its advanced digital control panel. This user-friendly interface provides real-time monitoring of key parameters, such as voltage, frequency, and total runtime. It simplifies the operation and maintenance of the generator, enabling users to make informed decisions about power management. The control panel also includes safety features, such as low oil pressure and high-temperature shutdowns, to protect the engine from potential damage.

The DCA-56SPX is also equipped with a sound-attenuated enclosure, significantly reducing noise levels during operation. This feature is particularly beneficial in urban environments or areas where quiet operation is a priority. Moreover, the durable, weather-resistant design of the generator ensures reliable performance in various outdoor conditions.

Portability is another key characteristic of the DCA-56SPX. The generator is fitted with heavy-duty wheels and a sturdy frame that allows for easy transport across job sites. In addition to its mobility, the unit is designed for easy access to service points, facilitating quick maintenance and minimizing downtime.

Flexibility is further enhanced by the generator's multiple output options, including 120/240V single phase and 120/208V three-phase configurations. This versatility allows users to connect various tools and equipment, making the DCA-56SPX suitable for numerous applications, from powering construction machinery to providing backup power during outages.

Overall, the Multiquip DCA-56SPX stands out due to its robust design, efficient engine, advanced control technologies, and user-oriented features. It is an excellent investment for those seeking a reliable power source that can handle demanding tasks while ensuring safety, portability, and efficiency. Whether for construction, event planning, or emergency situations, the DCA-56SPX delivers dependable performance to meet diverse power needs.