WET
HANDS

DCA-220SSJ/SSJU — RULES FOR SAFE OPERATION

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

The following safety recommendations should also be followed:

ALWAYS make sure generator is properly grounded.

NEVER use gas piping as an electrical ground.

DANGER - ELECTROCUTION HAZARDS

During operation of this generator, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

To avoid these hazards:

NEVER use damaged or worn cables when connecting equipment to the generator. Make sure power connecting cables are securely connected to the generator’s output terminals, insufficient tightening of the terminal connections may cause damage to the generator

and electrical shock.

ALWAYS make sure that electrical circuits are properly

grounded per the National Electrical Code (NEC) and

local codes before operating generator. Severe injury or

DEATH! by electrocution can result from operating an

ungrounded generator.

ALWAYS be sure to use the ground terminal (green wire)

when connecting a load to the U,V, and W output

terminal lugs.

Electrical Safety

ALWAYS have a qualified electrician perform the generator wiring installation.

ALWAYS make sure generator installation is accordance with the National Electrical Code (NEC) and local codes before operating generator.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper extension cord has been selected for the job. See Table 6.

NEVER power cables or cords lay in water.

NEVER stand in water while AC power from the generator is being transfer to a load.

NEVER grab or touch a live power cord with wet hands.

NEVER touch output terminals during operation. This is extremely dangerous. ALWAYS stop the machine and place the circuit breaker in the OFF position when contact with the output terminals is required.

Backfeed to a utility system can cause electrocution and or property damage. DO NOT connect to any building's electrical system except through an approved device or after building main switch is opened. ALWAYS have a licensed electrician perform the installation

POWER

CORD

(POWER ON)

DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #1 (02/28/14) — PAGE 11

Page 11
Image 11
Multiquip C1870300404, M4870300104B DCA-220SSJ/SSJU Rules for Safe Operation, Generator Grounding, Electrical Safety

C1870300404, M4870300104B specifications

Multiquip, a leading manufacturer in the construction and industrial sectors, offers a wide range of durable and reliable products. Among its extensive portfolio, two notable models stand out: the M4870300104B and the C1870300404. These models are particularly praised for their efficiency, innovative technologies, and robust features that cater to various construction needs.

The Multiquip M4870300104B is a powerful multi-process welder, designed to tackle a wide variety of welding applications. This model is equipped with an advanced inverter technology that allows it to deliver smooth and stable arcs for TIG, MIG, and Stick welding. The inverter design also enhances energy efficiency, making it an ideal choice for both on-site and workshop use. Furthermore, the M4870300104B features a dual-voltage capability, supporting both 120V and 240V input, which provides flexibility for different job sites.

In terms of usability, the M4870300104B boasts an intuitive control panel that allows for easy adjustments. Its lightweight design ensures easy transport, while the rugged construction promises durability in demanding environments. With a duty cycle of 35% at 200 Amps, this welder is built for efficiency and long-lasting performance, making it suitable for both professional and DIY applications.

On the other hand, the C1870300404 is a high-performance concrete vibratory screed that plays a crucial role in ensuring smooth finishes on concrete surfaces. This model is engineered with advanced vibration technology which allows it to efficiently remove air pockets and stabilize the concrete. The C1870300404 features a robust aluminum frame, enhancing its durability while maintaining a lightweight structure for ease of handling.

Equipped with a powerful and reliable engine, the C1870300404 offers impressive runtime, allowing crews to work continuously without frequent interruptions. It also features adjustable vibration settings, enabling users to customize the intensity based on the specific requirements of the project at hand. The ergonomic design of the handle contributes to user comfort, reducing fatigue during extended periods of operation.

In conclusion, both the Multiquip M4870300104B and C1870300404 exemplify the brand’s commitment to quality, innovation, and user-centric design. These tools not only enhance productivity but also guarantee precision and efficiency in various construction tasks. Whether for welding or concrete finishing, Multiquip continues to deliver equipment that meets the evolving demands of the industry.