DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #1 (02/28/14) — PAGE 25
1
2. The main menu will pop up on the display. Use the “Arrow
Buttons” to scroll through the menu until the “Engine
Configuration” menu item has been highlighted.
3. Once the “Engine Configuration” menu item has been
highlighted touch the “Enter Button” to view the engine
configuration data.
4. Use the “Arrow Buttons” to scroll through the engine
configuration data.
5. Touch the “Menu Button” to return to the main menu.
6. Touch the “Menu Button” to exit the Main menu and
return to the engine parameter display.
FAULTS AND WARNINGS
Auxiliary Gage Fault
1. During normal operation the single or four parameter
screen will be displayed.
2. The PVA Series of auxiliary gages can be attached to
the PowerView. These auxiliary gages communicate with
the Modbus master PowerView via a daisy-chained RS-
485 port. If at any time during system initialization or
normal operation an auxiliary gage should fail, the single
or four parameter screen will be replaced with the “MLink
Gage Fault” message.
3. To acknowledge and “Hide” the fault and return to the
single or four parameter display, touch the “Enter Button”.
4. The display will return to the single or four parameter
screen.
GOTO 1-UP DISPLAY
STOREDCODES
ADJUSTBACKLIGHT
SETUP1-UP DISPLAY
SETUP-4-UPDISPLAY
SELECTUNITS
ENGINECONFG
GOTO 1-UP DISPLAY
STOREDCODES
ADJUSTBACKLIGHT
SETUP1-UP DISPLAY
SETUP-4-UPDISPLAY
SELECTUNITS
ENGINECONFG
ENGINESPEED PT 1
1800 RPM
MORE
ENGINESPEED PT 1
1800 RPM
MORE
COOL
1800 RPM
01500 3000
TEMP
ENGRPM
98%
14.2 57PSI
1000RPM
LOADRPM
BATTVOLT
ENGRPM
OILPRES
ENGINEOIL PRESSURE
GAGENOT RESPONDING
1ofx
HIDE
ENGINEOIL PRESSURE
GAGENOT RESPONDING
1ofx
HIDE
COOL
1800 RPM
01500 3000
TEMP!
ENGRPM
!
98%
14.2
!
57PSI
1000RPM
LOADRPM
BATTVOLT
ENGRPM
OILPRES
!
DCA-220SSJ/SSJU — DIAGNOSTIC DISPLAY