DCA-220SSJ/SSJU — MAINTENANCE (ENGINE)

TABLE 14. INSPECTION/MAINTENANCE

 

10 Hrs

250 Hrs

500 Hrs

 

1000 Hrs

 

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

 

X

 

 

 

 

 

 

 

 

 

 

 

ENGINE

Clean Air Filter

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Fuel Filter/Water Seperator Bowl

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

 

X

 

 

 

Replace Air Filter Element * 3

 

 

 

X

 

 

 

Check all Hoses and Clamps * 4

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

 

 

X

 

 

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance Over 3M ohms

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Replace engine oil anf filter at 100 hours, first time only.

 

 

 

 

 

*2

Add "Supplemental Coolant Addatives (SCA'S)" to recharge the engine coolant.

 

 

 

 

*3 Replace primary air filter element when restriction indicator shows a vaccum of 625 mm (25 in. H20).

 

 

*4

If blowby hose needs to be replaced, ensure that the slope of the bloby hose is at least a 1/2 inch per foot, with

 

 

no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks.Use Table 14 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)

Air Cleaner

Every 250 hours: Remove air cleaner element and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Service Daily

If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result. This can lead to

aloss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations).

Removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally inspect the fuel tank for water contamination and drain the contents if required.

During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.

DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #1 (02/28/14) — PAGE 57

Page 57
Image 57
Multiquip C1870300404, M4870300104B operation manual DCA-220SSJ/SSJU Maintenance Engine

C1870300404, M4870300104B specifications

Multiquip, a leading manufacturer in the construction and industrial sectors, offers a wide range of durable and reliable products. Among its extensive portfolio, two notable models stand out: the M4870300104B and the C1870300404. These models are particularly praised for their efficiency, innovative technologies, and robust features that cater to various construction needs.

The Multiquip M4870300104B is a powerful multi-process welder, designed to tackle a wide variety of welding applications. This model is equipped with an advanced inverter technology that allows it to deliver smooth and stable arcs for TIG, MIG, and Stick welding. The inverter design also enhances energy efficiency, making it an ideal choice for both on-site and workshop use. Furthermore, the M4870300104B features a dual-voltage capability, supporting both 120V and 240V input, which provides flexibility for different job sites.

In terms of usability, the M4870300104B boasts an intuitive control panel that allows for easy adjustments. Its lightweight design ensures easy transport, while the rugged construction promises durability in demanding environments. With a duty cycle of 35% at 200 Amps, this welder is built for efficiency and long-lasting performance, making it suitable for both professional and DIY applications.

On the other hand, the C1870300404 is a high-performance concrete vibratory screed that plays a crucial role in ensuring smooth finishes on concrete surfaces. This model is engineered with advanced vibration technology which allows it to efficiently remove air pockets and stabilize the concrete. The C1870300404 features a robust aluminum frame, enhancing its durability while maintaining a lightweight structure for ease of handling.

Equipped with a powerful and reliable engine, the C1870300404 offers impressive runtime, allowing crews to work continuously without frequent interruptions. It also features adjustable vibration settings, enabling users to customize the intensity based on the specific requirements of the project at hand. The ergonomic design of the handle contributes to user comfort, reducing fatigue during extended periods of operation.

In conclusion, both the Multiquip M4870300104B and C1870300404 exemplify the brand’s commitment to quality, innovation, and user-centric design. These tools not only enhance productivity but also guarantee precision and efficiency in various construction tasks. Whether for welding or concrete finishing, Multiquip continues to deliver equipment that meets the evolving demands of the industry.