Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the diagnosis based on the Troubleshooting (Table 3) information shown below.

If the problem cannot be remedied, please leave the unit just as it is and consult or company's service department.

TABLE 3. TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Is ballast cable securely connected?

Plug in correctly.

 

 

 

 

Are generator and light tower switched on?

Turn on switch.

 

 

 

 

Is lamp loose?

Screw lamp securely into socket.

 

 

 

 

Are any other electric appliances (other

 

 

than light tower) plugged into power

Unplug all other appliances.

Lamp does not light.

source?

 

 

 

 

Is generator voltage normal (non-load

Repair or replace generator.

 

voltage - 110 VAC)?

 

 

 

 

 

 

Is model of lamp compatible?

Use genuine MQ lamp.

 

 

 

 

Is lamp cool enough to light again?

 

 

(Interval of 20 to 30 minutes is required

Wait for lamp to cool down.

 

before turning on lamp again)

 

 

 

 

 

Is generator voltage normal (non-load

Repair or replace generator.

Lamp only lights for a

voltage - 110 V)?

 

short time.

Is ambient temperature too high (more than

Move lamp where there is proper

 

 

104 °F (40 °C)?

ventilation.

 

 

 

Balloon does not

Is blower working properly?

Check or recharge blower.

 

 

inflate.

Does balloon have a leak?

Repair or replace balloon.

 

 

 

 