Multiquip MLT25 operation manual inspection, before starting, Danger

Models: MLT25

1 50
Download 50 pages 56.3 Kb
Page 16
Image 16
before starting

before starting

1.Read all safety instructions at the beginning of manual.

2.Clean the light tower, removing dirt and dust, particularly the engine cooling air inlet and air cleaner.

3.Check the air filter for dirt and dust. If air filter is dirty, replace air filter with a new one as required.

4.Check all fastening nuts and bolts for tightness.

inspection WARNING

The engine's exhaust contains harmful emissions. ALWAYS ventilate the exhaust when operating inside tunnels, excavations or buildings. Direct exhaust away from nearby personnel.

Before starting the engine, make sure of the following:

„„The electrical load is disconnected and the main circuit breaker and all lamp circuit breakers are switched to the OFF position.

DANGER CAUTION

NEVER start the engine with any circuit breakers in the ON position.

„„Light tower is placed on secure level ground with chock blocks underneath each wheel to prevent the light tower from rolling.

„„Outriggers have been fully extended to prevent the trailer from tipping.

„„Light tower trailer support stands have been positioned properly and the trailer is level.

„„Lamps have been adjusted to desired position.

„„Chocked blocks have been positioned under each wheel to prevent trailer from rolling.

„„Light tower trailer frame has been grounded correctly. „„Lamps do not interfere with any overhead obstructions.

inspection

DANGER

ALWAYS make sure the area above light tower is open and clear of overhead power lines and other obstructions. The tower extends in excess of 30 ft. (9 meters). Contact with overhead power lines or other obstructions could result in equipment damage, serious injury or death!

„„Lamp power cables have been plugged into the appropriate receptacles (J1-J6) on the T-Bar assembly. Follow instructions below to correctly install the power cable plugs.

a.Locate the 6 key-lock, 3-pin, female connectors on the T-bar. See Figure 4.

FRONT

REAR

LAMP 1

LAMP 4

LAMP 2 Manual backgroundManual backgroundManual background

LAMP 5

LAMP 3

LAMP 6

Manual background T-BAR

MAST RAISED

 

 

J3

J2

J1

 

 

 

 

 

 

 

 

 

 

J6

J5

J4

 

 

 

 

 

 

 

 

 

 

 

FEMALE CONNECTORS

 

 

 

 

 

LOCKING NUT

 

 

 

 

 

(MALE CONNECTOR)

 

 

 

 

 

Figure 4. T-Bar and Cable Connectors

page 16 — MLT25 sERIES LIGHT TOWER • operation manual — rev. #0 (11/28/12)