  | TROUBLESHOOTING | |
  | 
  | 
  | |
  | 
  | 
  | |
  | Table 5. Lamp Troubleshooting (continued) | ||
  | 
  | 
  | |
Symptom | Possible Cause  | Solution  | |
  | 
  | 
  | |
Lamp starts slowly | 
  | 
  | |
(ARC does not strike | Defective Lamp? | Lamp may glow for extended period of time. Replace after  | |
when switch is first | checking voltage and ballast. | ||
  | |||
turned on) | 
  | 
  | |
  | 
  | 
  | |
Circuit breaker trips on  | Short Circuit or Ground?  | Check wiring against diagram. Check for shorts or ground.  | |
lamp  | |||
  | 
  | ||
  | 
  | 
  | |
  | Normal Lamp  | Replace Lamp.  | |
  | Depreciation?  | ||
  | 
  | ||
  | 
  | 
  | |
  | Dirty Lamp or Fixture?  | Clean lamp and fixture.  | |
  | 
  | Interchange ballast plugs in generator enclosure. If lamp  | |
Lamp light output low | Defective Ballast? | returns to normal light output, replace ballast. Check for  | |
swollen capacitor, charred wiring, core and coil, or other signs  | |||
  | |||
  | 
  | of excessive heat. | |
  | 
  | 
  | |
  | 
  | Check voltage at ballast input. Voltage should be within 10%  | |
  | Wrong Voltage? | of nameplate rating. Check wiring connections for voltage  | |
  | 
  | loss. Check socket contact point. | |
  | Improper Ballast? | Check ballast nameplate against lamp data. | |
  | 
  | 
  | |
  | 
  | Lamp output and brightness decreases and color changes  | |
  | Normal Lamp | slightly as lamps age. Spot replacement with new lamps  | |
  | Depreciation?  | may cause noticeable differences in lamp colors. Group  | |
Lamp colors different.  | 
  | replacement minimizes color differences. | |
  | 
  | ||
Dirty Fixture? | Dirty fixtures will cause lamps to appear different in color.  | ||
  | |||
  | Clean fixture. | ||
  | 
  | ||
  | 
  | 
  | |
  | Wrong Lamp? | Check data on lamps which appear different in color. Replace  | |
  | with correct color lamp. | ||
  | 
  | ||
  | 
  | 
  | |
  | Over Voltage from Power  | Check voltage at ballast. Check for current or voltage surges.  | |
ARC tube discolored or  | Supply? | Check for shorted capacitors and replace if defective.  | |
swollen. | Improper Ballast? | Lamp operated on ballast designed for higher wattage lamp.  | |
  | Check ballast nameplate against lamp data.  | ||
  | 
  | ||
  | 
  | 
  | |
  | 
  | Check for outer bulb cracks. If air enters outer bulb, arc tube  | |
  | 
  | may continue to burn for 100 hours before failure. Check for  | |
  | 
  | bulb cracks where glass meets the base due to tightening  | |
  | Lamp Damaged? | Lamp too firmly in socket or scoring of glass where socket  | |
Short lamp life. | 
  | inadvertently touches the lamp bulb. Look for broken arc tube  | |
  | or loose metal parts. Replace lamp. (Bulb leads will cause  | ||
  | 
  | ||
  | 
  | oxidation of metal parts.) | |
  | 
  | 
  | |
  | 
  | Ballast nameplate data should agree with lamp line voltage  | |
  | Improper Ballast? | and lamp use. If improper ballast is used, the lamp life will be  | |
  | 
  | shortened. A mismatch may also cause the ballast to fail.  | |
MLT25 SERIES LIGHT TOWER • operation manual — rev. #0 (11/28/12) — page 43