Multiquip MQ62TDD manual Startup/Operation, Engine Startup

Models: MQ62TDD

1 116
Download 116 pages 33.79 Kb
Page 25
Image 25

ENGINE STARTUP

CAUTION — Equipment Damage Hazards

DO NOT attempt to start the engine unless the pump has previously been primed with water. Severe damage to the pump's mechanical seal will occur if pump has not been primed.

1.Set the Engine Speed Control Lever (Figure 12) to a position half way between start and stop.

ENGINE SPEED

 

CONTROL

FULL THROTTLE

LEVER

(RUN POSITION)

STOP

Figure 12. Engine Speed Control Lever

2.Insert ignition key into ignition switch (Figure 13), turn ignition key clockwise to position I, and verify that all three status indicator lights (Figure 14) are ON.

 

0

I

P

 

 

 

II

III

Figure 13. Ignition Switch

3.Continue turning ignition key through positions II and III while pushing the red button at the same time.

4.Release ignition key and red button as soon as engine fully starts, and verify that ignition key automatically returns back to position I. Verify that all three lamp/ LED status indicator lights are OFF when the engine is started.

STARTUP/OPERATION

 

H

 

 

 

 

 

OU

RS

 

 

REDDEPRESSEDFOR

 

 

 

 

 

UP

 

 

 

 

 

BUTT ART

 

 

 

 

 

ST

 

 

 

 

 

ENGINE

 

 

 

 

 

BE

 

 

 

 

 

 

 

 

 

 

OFF

 

FU

SE LO

 

 

 

 

 

CATED IN

 

 

 

 

 

 

RUN

 

 

 

SIDE P

ANEL

LAMP

LED

 

 

 

START

STATUS

STATUS

 

 

 

 

 

 

 

INDICATORS

INDICATORS

 

 

 

 

Figure 14. Engine Status Indicators Lamps

8.If charge lamp or LED remains lit, increase engine speed until lamp/LED goes off. When the charge indicator lamp/LED goes off, it can then be assumed that the charging system is working correctly.

9.If the charge lamp or LED remains on while the engine is running, refer to Table 12 (Engine Troubleshooting) or the Deutz Engine Repair Manual.

10.Move speed control lever to full speed position for maximum engine speed. (See Figure 12)

OPERATION

1.The pump should begin pumping water within a minute depending on the length of suction hose and height the pump is above water.

2.If pump does not begin to pump water after a few minutes, check for loose connections or air leaks in suction hose. Make sure there is water in the pump end and strainer is not clogged with debris, reference Table 11 (Pump Troubleshooting).

Longer suction hoses will require more time for the pump to begin pumping water.

MQ62TDD TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #0 (07/30/09) — PAGE 25

Page 25
Image 25
Multiquip MQ62TDD manual Startup/Operation, Engine Startup

MQ62TDD specifications

The Multiquip MQ62TDD is a robust engine-driven compressor designed to deliver exceptional performance and reliability in challenging job site conditions. This portable unit is engineered for a wide range of applications, including construction, HVAC, and industrial use. With its powerful engine and user-friendly features, the MQ62TDD stands out as an ideal choice for contractors needing dependable air supply on the go.

One of the primary features of the MQ62TDD is its impressive air output. The unit boasts a maximum air flow rate of up to 62 CFM, allowing it to power multiple pneumatic tools simultaneously. Whether you are operating jackhammers, nail guns, or air impact wrenches, the MQ62TDD ensures consistent and sufficient air pressure to keep your projects moving efficiently.

The MQ62TDD is equipped with a 9-horsepower Honda engine, providing the necessary power to drive the compressor. Honda engines are renowned for their durability and fuel efficiency, and this model is no exception. With an extended run time due to its large fuel tank, the MQ62TDD minimizes downtime, which can be crucial in time-sensitive projects.

In terms of technological advancements, the MQ62TDD features an advanced cooling system designed to keep the compressor operating at optimal temperatures, thus extending the lifespan of the unit. The unit’s lightweight design, combined with a sturdy frame, makes transportation on site straightforward. The integrated handle and collapsible wheels facilitate easy maneuverability, ensuring that the compressor can be relocated without hassle.

Safety is also a priority with the Multiquip MQ62TDD. The unit is designed with protective features such as a low oil shutdown mechanism, which helps to prevent engine damage by automatically turning off if the oil level gets too low. Additionally, the compressor features sound-dampening technology that significantly reduces noise levels, making it ideal for use in noise-sensitive environments.

Overall, the Multiquip MQ62TDD compressor is a versatile, durable, and user-friendly tool that meets the demands of professional contractors. With its high air output, reliable power source, advanced technologies, and safety features, it provides the efficiency and performance needed to tackle any job with confidence.