N-Tron 102PC-SE user manual Recv-mail Configure incoming mail options

Models: 102PC-SE

1 40
Download 40 pages 11.6 Kb
Page 15
Image 15

o

recv-mail

(Configure incoming mail options)

 

￿

leave-on-server

(enable or disable to leave messages on the server)

 

￿

mailbox-name

 

(set the mailbox’s name)

 

￿

mailbox-password

(set the mailbox’s password)

 

￿

server-name

 

(set the server’s name)

 

￿

server-port

 

(set the server’s port number)

o

send-mail

(Configure outgoing mail options)

￿smtp-server-name

￿smtp-server-port

￿host-name

￿from-address

￿from-address-identity

￿to-address

￿cc-address

￿reply-to-address

￿subject

(set the smtp server name)

(set the smtp server port number) (set the host name)

(set the mail ID for the from address, ex. info@n-tron.com) (string associated with the mail ID, ex. N-Tron)

(set the to mail address field) (set the cc mail address field) (set the mail ID reply to address) (set the subject field of the message)

o serial

(Configure the serial settings for the serial port s0)

￿

auto-dialin

(enable or disable auto-dialin)

￿

escape-monitor

(enable or disable escape monitor)

￿

escape-string

(set the escape string, default ‘+++inet’)

￿

s0

(configuration options for serial port s0)

 

auto-dialin

(configure auto dialin settings)

 

 

o

enable/disable

 

(enable or disable auto-dialin)

 

 

o

message

 

(enable or disable auto-dialin message)

 

o

trig-mode

 

(char, dtr, dtr-char, or none trig mode options)

 

auto-dialin-ipaddress

(set an IP address for the auto-dialin feature)

 

auto-dialin-port

(set the port number for the auto-dialin feature)

 

auto-dialin-protocol

(telnet)

 

 

auto-dialout

(enable or disable auto dialout)

 

auto-dialout-port

(set the port number for the auto-dialout feature)

 

auto-dialout-protocol

(telnet)

 

 

baud-rate

 

(Possible baud-rate value(s) are 300 600 1200 1800 2400 4800 9600 19200 38400 57600

 

 

 

 

115200 230400)

 

buffer-datasize

(Buffer data-size range: [1-1500] bytes)

 

buffer-time

(set a buffer time in seconds, 0 for no buffer)

 

chat-script

(Chat-script is used to establish physical link from the dialing to answering end in case of

 

 

 

 

modem connect, when modem dialing-method is set to chat-script.)

 

connect-state

(answering or dialing state)

 

connect-type

(direct or modem connect type)

 

data-bits

 

(set the number of data-bits over the serial line, default is 8 bits)

 

dialout-monitor

(set the dialout monitor to dtr or none)

 

echo-command

(enable or disable the echo command)

 

flow-control

(rts-cts or none)

 

host-interaction-mode

(enable or disable host interaction mode)

 

login-string

(string up to 8 characters)

 

modem

 

(modem configuration)

 

 

o

connect-string

 

(set the connect string for a modem)

 

 

o

dial-number

 

(set the number to dial)

 

 

o

dial-prefix

 

(any prefix dialing needed can be set here)

 

 

o

dial-suffix

 

(any suffix dialing needed can be set here)

 

 

o

dialing-method

(use configuration of chat-script)

 

 

o

hangup-string

 

(set string used to hang up the line)

 

 

o

init-string

 

(set init number [1-5])

 

 

o

ok-string

 

(set an ok string)

 

o

ring-string

 

(set a ring string)

 

parity

 

(none, odd, or even parity)

 

raw-dialin

(enable or disable raw-dialin)

 

raw-dialout

(enable or disable raw-dialout)

 

stop-bits

 

(set the number of stop bits [1, 1.5, or 2])

o

time

(Set system time HH:MM:SS)

o

watchdog

(Enable or disable watchdog)

(continued…)

12/1/2006

15

Page 15
Image 15
N-Tron 102PC-SE user manual Recv-mail Configure incoming mail options, Send-mail Configure outgoing mail options