Scenario 1 – Manual Serial Dial-in

Login in to the Command prompt from the serial side.

Invoke # telnet <ip-address> <port> at the command prompt. Once the session is opened successfully, there can be two-way traffic between the serial device and the remote server.

You can switch from Command Prompt to Dial-in session using restore session command.

You can switch from Dial-in session to Command Prompt using <escape-monitor-string>.

Manual Dial-in Feature Through the Command Shell

Commands to Setup Manual Dial-In with the 102PC-SE

#set ip eth0 dhcp-client disable

#set ip eth0 ip-address 192.168.2.1

#set serial s0 baud-rate 115200

#set serial s0 data-bits 8

#set serial s0 parity none

#set serial s0 stop-bits 1

#set serial s0 flow-control rts-cts

#save

Once the above configuration is saved on the 102PC-SE, login to the 102PC-SE through the serial port. At the command shell invoke:

# telnet 192.168.2.10 23

The telnet client on board in the 102PC-SE establishes a virtual serial tunnel between the serial device and the Telnet Server.

Notes:

1.You can not open more than one dial-in session.

2.The dial-in session is closed when the telnet session is closed.

3.When escape-monitoris enabled, care should be taken during file transfer that the escapemonitor- ring is not part of the data.

4.The manual dial-in is supported for Telnet ONLY and not for UDP.