Ethernet to Serial Connectivity

Mandatory Configuration Settings

The following items must be configured in order to use the manual dial-out feature:

Disable the Host Interaction Mode to restrict Telnet-Dial-Out and PPP.

#set serial <s0> host-interaction-mode disable

Disable Auto dial-out globally on all the serial ports.

#set ip auto-dialout disable

Disable Auto dial-out on the serial port s0.

#set serial s0 auto-dialout disable

The following items must be configured in order to use the auto dial-out feature:

Disable the Host Interaction Mode to restrict Telnet-Dial-Out and PPP.

#set serial <s0> host-interaction-mode disable

Enable Auto dial-out globally on all the serial ports.

#set ip auto-dialout enable

Enable Auto dial-out on the serial port s0.

#set serial s0 auto-dialout enable

Set the Auto dialout port for the serial port s0 .

#set serial s0 auto-dialout-port <port_number>

Set the Auto dialout protocol for the serial port s0.

#set serial s0 auto-dialout-protocol <telnet or udp>/all

An ERROR message will display if any of the above details are not configured or are not valid.

Optional Configuration Settings

The following details are optional configurations:

Enable/Disable the Authentication for Dial-out session

#set login auto-dialout-login <enable/disable>

Enable/Disable the Switching-between-Dialout & CommandPrompt feature

#set ip telnet escape-monitor <enable/disable>

Set the Escape-Monitor-String to switch between Dialout and Command Prompt sessions.

#set ip telnet escape-string "+++inet"

Enable/Disable the Terminating Dialout Session using Terminate string

#set ip udp terminate-monitor <enable/disable>

Set the Terminate-Monitor-String to Terminate the Dialout Session.

#set ip udp terminate-string "+++inet"

Enable/Disable the Terminating Dialout Session using Inactivity Timeout

#set ip udp inactivity <enable/disable>

Set the Inactivity Timeout to Terminate the Dialout Session.

#set ip udp inactivity-timeout 300

Enable/Disable the Raw mode globally for all Dial-out sessions.

#set ip telnet raw-mode <enable/disable>

Enable/Disable the Raw mode for the serial port s0.

#set serial s0 raw-dialout <enable/disable>

Set the Baud rate for the serial port s0 to be taken for a Dialout session.

#set serial s0 baud-rate <Baud-rate>

Set the Flow control for the serial port s0 to be taken for a Dialout session.

#set serial s0 flow-control <rts-cts/none>

Set the Parity for the serial port s0 to be taken for a Dialout session.

#set serial s0 parity <even/odd/none>

Set the Data bits for the serial port s0 to be taken for a Dialout session.

#set serial s0 data-bits <7/8>

Set the Stop bits for the serial port s0 to be taken for a Dialout session.

#set serial s0 stop-bits <1/1.5/2>