FRAMING

 

FRAMING

The

can be installed with a rectangular opening.

It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4’s and frame to local build- ing codes.

Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fi replace body, it is recommended that the walls of the fi replace enclosure

13

CLEARANCE TO COMBUSTIBLES

MAINTAIN THESE MINIMUM CLEARANCES TO COMBUS- TIBLES:

Fireplace framing - 0” to stand-offs (top, rear & sides) Fireplace finishing - 4 3/4” to sides of fireplace opening.

- 22 3/8” to top of fireplace opening.

FIGURE 28

be “fi nished” (ie: drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.

For convenience, the stand-offs have been shipped flat. Before framing, ensure the stand-offs are opened and screwed in place.

It is not necessary to install a hearth extension, but the fi re- place should be raised to be fl ush with either the hearth or the fi nished fl oor.

When roughing in the fi replace, raise the fi replace to accom- modate for the thickness of the fi nished fl oor materials, i.e. tile, carpeting, hard wood, which if not planned for will interfere

NON-COMBUSTIBLE

FINISHING MATERIAL

60 3/4"

 

 

 

 

Non-combus-

 

 

 

 

tible finishing

 

 

 

 

material (ie:

 

 

 

 

 

22 3/8"

 

 

cement board,

 

 

 

brick, stone,

 

71

1/4"

 

 

 

 

tile) must be

 

 

 

 

 

 

 

 

used to finish

 

 

 

 

the front facing

 

 

 

 

of the unit.

 

 

 

 

 

 

 

 

 

 

43/4"

with the removal of the hearth strip, which must be removed to access the fi rebox.

Objects placed in front of the fi replace should be kept a mini- mum of 48” away from the front face.

1"

 

FIGURE 26

MIN

 

 

1"

 

 

MIN

 

 

82"

 

 

 

 

"

 

59

1/4

 

116"

 

 

 

 

72"

 

 

59 1/4"

 

 

29"

 

 

FIGURE 27

 

 

29"

 

59 1/4"

 

IMPORTANT:

The CLEARANCE TO COMBUSTIBLESManual backgroundManual background requires a minimum inside enclosure height of 72”. Measured from the bottom of the fire- place.

For temperature require- ments, this area must be left unobstructed.

It is recommended that the enclosure be ventilated at the top and bottom to circu- late the hot air.

*Non combus- tible material

must extend NON-COMBUSTIBLE

72” at which top of enclo- sure can be combustible

COMBUSTIBLE

Manual backgroundMATERIALManual background

 

FIRESTOP

 

SPACER

STUD

2"

 

2"

STAND OFF

 

SPACER

 

 

FIGURE 29

29"

 

59 1/4"

10"

 

MIN

WARNING

Facing and/or finishing

material must never

overhang into the fireplace

opening.

W415-0614 / A / 07.24.07