FOR YOUR SAFETY READ BEFORE

24

FOR YOUR SAFETY READ BEFORE

LIGHTING:

A.This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B.Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor.

C.Use only your hand to turn the gas control knob / manual shut-off knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualifi ed service technician. Force or attempted re pair may result in a fi re or explosion.

D.Do not use this fi replace if any part has been under water. Immediately call a qualifi ed service technician to inspect the fi replace and replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

Warning: if you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. Initial lighting of the pilot and main burners must be done with the glass door off.

Do not connect valve or wall switch to electricity. See installation instructions.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob it depressed slightly.

1.STOP! Read the safety information on the operating label.

2.Turn off all electric power to the fi replace.

3.Turn the gas knob clockwise LIGHTING INSTRUCTIONS to off.

4.Wait 5 minutes to clear out any gas. If you smell gas, including near the fl oor, STOP! Follow “B” on the op- erating label. If you don’t smell gas, go to the next step.

5.If the fi replace is equipped with a fl ame adjustment valve, turn clockwise to off.

6.Find pilot located in front of the back log on the right.

7.Turn gas knob clockwise OPERATING INSTRUCTIONS to pilot.

8.This unit is equipped with an auto-spark. Depress and hold gas knob . Keep knob fully depressed for one minute, then release. If pilot does not continue to burn repeat steps 3 through 7.

9.With pilot lit, push and turn gas knob counter-clock

wise WHAT TO DO IF YOU SMELL GAS to on.

10.If equipped with fl ame adjustment valve, turn knob to high.

11.If equipped with remote on-off switch, main burner may not come on when you turn the valve to on or high. Remote switch must be in the

on position to ignite burner.

12.Turn on all electric power to the fi replace.

FIGURE 50

OPERATING INSTRUCTIONS

When lit for the fi rst time, the fi replace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to suffi ciently ventilate the room.

After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to suffi ciently ventilate the room.

Purge all gas lines with the glass door of the fireplace removed. Assure that a continuous gas flow is at the burner before installing the door.

WHAT TO DO IF YOU SMELL GAS

Do not touch any electric switch.

Do not use any phone in your building.

If you cannot reach your gas supplier, call the fi re department.

Turn off all gas to the fi replace.

Do not try to light any appliance.

Immediately call your gas supplier from a

neighbor’s phone. Follow the gas ILO

supplier’s instructions.P T

 

F

O

 

F

N

FIGURE 51

O

 

 

 

 

GAS KNOB

 

TO TURN OFF GAS

1.Turn off all electric power to the fi replace if service is to be performed.

2.For a complete shut-down procedure: push in gas

control knob slightly and turn clockwise TO TURN OFF GAS to off. Do not force.

3.For a temporary shut-down procedure: set the switch to off. Press and turn the gas knob clockwise Manual background to pilot.