Napoleon Fireplaces BGD90NT Adjustments, Maintenance, Fuel Conversion, Burner, Natural Gas, Front

Models: BGD90PT BGD90NT

1 32
Download 32 pages 7.27 Kb
Page 25
Image 25
MAINTENANCE
PILOT
HOOD
PILOT
INJECTOR
Fig. 3

25

MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER

BEFORE SERVICING THE FIREPLACE. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after ser- vicing. This fi replace and its venting system should be inspected before use and at least annually by a qualifi ed service person. The fi replace area must be kept clear and free of combustible materials, gasoline or other fl ammable vapours and liquids. The fl ow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shut- ter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4.Check to see that the pilot fl ame is large enough to engulf the thermocouple and thermopile and reaches toward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your NAPOLEON® dealer / distributor.

7.Check that the gasket on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

ADJUSTMENTS

FUEL CONVERSION

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

CAUTION: Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.

1.Remove the screen, hearth strip, door and log set from the fi replace. Refer to the FINISHING section of your installation manual for instructions.

Fig. 1

2.Remove the front burner. (4 screws) Then remove the retainers on the rear burner (2 screws) and lift out the rear burner. (Fig. 1)

Fig. 2

4.Before replacing the burners, adjust the air shutters according to the following table:

BURNER

NATURAL GAS

PROPANE

Front

5/32"

3/8"

Rear

3/16"
7/16"

5.Remove the burner hood from the pilot assembly by pulling vertically. Use a 5/32" allen key to unscrew the injector. Replace the pilot injector with the one supplied. Replace the pilot hood onto the assembly ensuring key position for proper alignment. (Fig. 3)

6.To convert the main valve to the desired fuel, follow

the instruction leaflet for the

SIT regulator assembly that is SIT included with this kit.

7. The conversion data label must be fi lled out and attached adjacent to the valve.

8.Replace and re-secure both burners ensuring that the

venturis fit over the burner orifi ces.

9.Turn on the gas supply and check for gas leaks by brushing on a soap and water solution.

Do not use open flame.

10.Replace the log set. Then light the pilot and main burner to ensure that the gas lines have been purged and that the fi replace is operating properly at 50,000 BTU's for both fuels. Refer to the lighting instructions in your fi replace installation manual.

11.Replace the door, hearth strip, and screen. Turn on the electrical supply to the fi replace.

3.Using a deep 9/16" socket wrench, remove both the rear and front burner orifi ces. A 7/8" back-up wrench must be used on the manifold, located below the housing to ensure that the aluminum tubing does not twist or kink. Using pipe thread compound, replace the front and rear orifices supplied.

Purge all gas lines with the glass door off.

Assure that a continuous flow is at the burner before replacing the door.

(Fig. 2)