Remote receiver

30

SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

Pilot burning; no gas to main burner; Flame height is on ‘HI’; Remote and transmitter ON

Remote receiver

- disconnect switch wires &connect a jumper wire across terminals

 

 

1 & 3; if the main burner lights, check the wires for defects and / or

 

 

replace wires.

Main burner orifice is

- remove stoppage in orifi ce.

plugged.

 

 

Faulty thermopile.

- test and replace if required.

Pilot goes out while

Gas piping is undersized.

- turn on all gas appliances and see if pilot fl ame fl utters, diminishes or

standing; Main

 

extinguishes, especially when main burner ignites. Monitor appliance

burner is in ‘OFF’

 

supply working pressure.

position.

 

-

check if supply piping size is to code. Correct all undersized piping.

Pilot will not light.

No spark at pilot burner

-

check if pilot can be lit by a match

PILOT

 

-

check that the wire is connected to the spark module.

BURNER THERMOPILE

-

check batteries.

THERMOCOUPLE

 

-

replace the wire if the wire insulation is broken or frayed.

 

-

replace the electrode if the ceramic insulator is cracked or broken.

 

 

 

 

-

replace spark module.

 

Out of propane gas

-

fi ll the tank.

 

Spark gap is incorrect

-

spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.) from

 

 

the electrode tip and the pilot burner. To ensure proper electrode loca-

 

 

tion, tighten securing nut (fi nger tight plus 1/4 turn).

 

No gas at the pilot burner

-

check that the manual valve is turned on.

 

 

-

check the pilot orifi ce for blockage.

 

 

-

call the gas distributor.

Main burner goes

Pilot flame is not large enough

-

turn up pilot fl ame.

out; pilot stays on.

or not engulfi ng the thermo-

- replace pilot assembly.

 

pile

 

 

 

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.

 

 

- test and replace thermopile if required.

 

Temperature setting on trans-

-

turn up temperature setting.

 

mitter is satisfi ed

 

 

Main burner goes out; pilot goes out.

Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”

Vent is blocked

-

check for vent blockage.

Vent is re-circulating

-

check joint seals and installation.

 

 

 

8” fl exible vent has become

-

re-attach to fi replace.

disconnected from fi replace.

 

 