Napoleon Fireplaces BGD90PT, BGD90NT manual Address Setting Procedure

Models: BGD90PT BGD90NT

1 32
Download 32 pages 7.27 Kb
Page 22
Image 22
ADDRESS SETTING PROCEDURE

22

ADDRESS SETTING PROCEDURE

Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address. Press the LEFT key to exit this function.

The transmitter address is required to be equal to the Receiver. (Figure 62) Select, through setting of the dip switches, the address of the receiver. (Figure 64) Switch #8 must always be in the ON position (down). It is also pos- sible to start a receiver address search sequence through the Transmitter. To enter this function use the DOWN or UP keys until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key tem times. The display will then show the present transmitter address. To alter the address of the Transmitter press the UP key to increase and DOWN to decrease it.

A “beep” from the Receiver will confi rm the same address as the Transmitter. Press LEFT key to exit this function.

Note: The address of the Receiver is acquired only at its power on. Changing the address while the Receiver is powered will not have any effect. To change the address of the Receiver, disconnect the power cable from the Receiver, change the address and reconnect the power cable to the Receiver.

FIGURE 48

FAHRENHEIT - Celsius Temperature Indication

It is possible to set the Remote Control to display the tempera- tures in either Fahrenheit or Celsius. Use the UP or DOWN key on the Transmitter until the cursor (small triangle) is left of the click icon. From time 0:00 press the LEFT key ten times. The display will show the transmitter address. Use the RIGHT key to toggle from ºF to ºC and vice versa. The display will show the selected unit of measure. Press the LEFT key to exit this function. (Figure 63)

FIGURE 49

W415-0614 / A / 07.24.07

Page 22
Image 22
Napoleon Fireplaces BGD90PT, BGD90NT manual Address Setting Procedure