OPERATING INSTRUCTIONS
When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room.
After extended periods of
slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.
Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.
FOR YOUR SAFETY READ BEFORE LIGHTING:
A.This fireplace is equipped with an ignition device which automatically lights the burner. Do not try to light by hand.
B.Before operating, smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.
C.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.
WHAT TO DO IF YOU SMELL GAS:
•Turn off all gas to the fireplace.
•Open windows.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
LIGHTING INSTRUCTIONS
1.STOP! Read the safety information located above.
2.Turn off all electric power to the fireplace.
3.This fireplace is equipped with an ignition device which automatically lights the burner. Do not try to light by hand.
4.Remove the glass door.
5.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor STOP! Follow “B” in the above safety information on this label. If you don’t smell gas go to the next step.
6.Replace the glass door.
7.Turn on all electric power to the fireplace.
8.Turn the fireplace switch to the ON position.
9.If fireplace will not operate, follow instructions “To Turn Off Gas” and call your service technician or gas supplier.
FIGURE 32
TO TURN OFF GAS
1. Turn the fireplace switch to the OFF position. | 3. Turn manual | off. |
2. Turn off all electrical power to the fireplace if service is to | Do not force. |
|
be preformed. |
|
|
RATING PLATE
RATING LABEL LOCATION: The rating label is located under the control panel and is chained to the fireplace.
DO NOT REMOVE.
|
| I |
| R |
| K |
|
|
| |||
|
|
|
|
| TE T |
|
|
|
|
| ||
|
|
| N |
| E |
|
|
|
| |||
C |
|
|
|
|
|
| CM |
|
|
|
| US |
W |
|
|
|
|
|
|
| y | ||||
|
|
|
|
|
|
|
| |||||
|
| a | r |
|
|
|
|
|
| e |
| |
|
|
|
|
|
|
| s |
| ||||
|
|
|
|
|
|
| r |
|
|
| ||
|
|
|
| nock He |
|
|
|
|
REFERENCE #15901
CERTIFIED UNDER : CSA
DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES. IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A.
MODEL | CERTIFIED FOR CANADA AND USA | MODEL | |||
GT8N |
|
|
| GT8P | |
|
|
|
|
(NATURAL GAS) |
| (PROPANE) |
ALTITUDE | ||
6,000 BTU/h | INPUT | 6,000 BTU/h |
#56 | ORIFICE | #69 |
MANIFOLD PRESSURE: 3.5" WATER COLUMN | MANIFOLD PRESSURE: 10" WATER COLUMN |
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN | MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN |
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN | MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN |
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP | 6” | RECESSED DEPTH | 7” |
FLOOR | 0” | VENT | 1” |
SIDES | 0” | BACK | 1 1/2” |
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING MATERIAL, SEE OWNERS MANUAL.
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
VENTED GAS FIREPLACE NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOOR. CERTIFIED WITH THIS UNIT ONLY.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS, SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A CERTIFIED KIT IS USED.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS |
|
|
| |
ARE 10 INCHES AND 10 FEET RESPECTIVELY. |
|
|
| |
MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS | SERIAL NUMBER: | GT8 | ||
ARE 36 INCHES AND 10 FEET RESPECTIVELY. | ||||
|
|