GAS INSTALLATION

GAS INSTALLATION

Proceed once the vent installation is complete.

Note: All gas connections must be contained within the fireplace when complete.

1.The fireplace is designed to accept a 1/2” gas supply line. The fireplace is equipped with a 1/2” manual shut-off valve.

2.The access to the gas inlet is located on the bottom of the outer shell.

3.The shut off must always be within the outer shell.

4.When flexing any gas line, support the gas valve so that the lines are not kinked.

5.Check for gas leaks by brushing on a soap and water solution.

Do not use open flame.

FIGURE 17

13

FIGURE 16

ELECTRICAL CONNECTION

!WARNING

RISK OF ELECTRIC SHOCK!

Control and valve operate with 110v.

Do NOT use the fireplace if any part has been under water. Call a qualified service technician IMMEDIATELY to have the fireplace inspected for damage to the electrical circuit.

HARD WIRING CONNECTION

IT IS NECESSARY TO HARD WIRE THIS

FIREPLACE.

Permanently framing the fireplace with an enclosure, requires the fireplace junction box to be hard wired.

This fireplace must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE in the United States.

FIGURE 18

 

 

GAS

 

 

 

 

 

VALVE

 

 

 

IGNITOR

 

 

 

 

 

IGNITOR

YELLOW

1

2

3 4

WIRE

 

 

 

 

 

BROWN

 

 

 

CONTROL MODULE

W

B

 

 

 

H

L

 

 

SWITCH

PURPLE

I

A

 

 

T

C

 

 

 

E

K

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

GROUND

 

 

 

 

 

110v

 

 

 

 

 

POWER

 

 

 

 

 

SUPPLY

JUNCTION BOX

 

 

 

 

(c/w 2 receptacles)

 

 

 

STAND-OFF ASSEMBLY

1

FIGURE 19a&b

2

W415-0619 / B / 03.03.08

Page 13
Image 13