FIGURE 2a

7

TYPICAL VENT INSTALLATIONS - HORIZONTAL TERMINATION

 

MIN

MAX

FIGURE

Allowable 3” vent connections (excluding fireplace and air terminal connections)

N/A

1

 

Rise per foot (recommended)

1/4”

N/A

 

Rise per foot (allowable)

0”

N/A

 

Horizontal run (If vent run does not include vertical rise)

4”

24”

2a

Horizontal run (if vent run includes vertical rise)

4”

7 FT

2b

Vertical run

18”*

7 FT

2b, 2c

(* Immediately off the fireplace, if 7 FT maximum horizontal run is required)

 

 

 

See graph to determine the required vertical rise VT for the required horizontal rise HT.