Napoleon Fireplaces GT8N Venting Lengths And Air Terminal Locations, Dimensions, FIGURES 1a-c

Models: GT8N Fireplace GT8P

1 22
Download 22 pages 19.67 Kb
Page 5
Image 5
DIMENSIONS
CARE OF GLASS AND PLATED PARTS
! WARNING
Do not substitute materials. Use care when handling glass components do not stike, or slam shut. Do not operate with broken glass.

5

The glass is 3/16” ceramic glass, available from your Napoleon® / Wolf Steel Ltd. dealer. Clean the glass after the first 10 hours of operation with a recommended gas

fireplace glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. If the glass is not kept clean permanent discolouration and / or blemishes may result.

 

 

DIMENSIONS

 

 

FIGURES 1a-c

 

 

1/4

43 3/4

 

37 3/4

 

 

3" DIA.

 

 

5" DIA.

ELECTRICAL

GAS LINE

2

ACCESS

ACCESS

 

 

VENTING

VENTING LENGTHS AND AIR TERMINAL LOCATIONS

The vent connection to the fireplace can be viewed by removing the baffle from the top, inside of the firebox.

Use only Wolf Steel venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. Use only Wolf Steel Ltd. flexible vent components with the Wolf Steel Ltd. GD179 termination kit. This fireplace uses a 3” exhaust and a 5” instake diameter coaxil vent system.

All outer pipe joints of these venting systems must be sealed using Red RTV and/or Mill Pac high temperature sealant (not supplied) hereafter referred to as high temperature sealant W573-0002 (Red RTV) and the high temperature sealant W573- 0007 (Mill Pac).

For vent systems that provide seals on the inner exhaust flue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the fireplace flue collar which must be sealed using the black high temperature sealant Mill Pac.

With flexible venting, in conjunction with the GD178 wall terminal kit, use either the 5 foot vent kit GDT5 or the 10 foot vent kit GDT10. These kits allow for extended horizontal venting of the fireplace.

When using approved Wolf Steel venting components, use only the following termination kits: WALL TERMINAL KIT GD178, or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT GDT110, 8/12 TO 12/12 ROOF TERMINAL KIT GDT111, FLAT ROOF TERMINAL KIT GDT112.

Rigid and flexible venting systems must not be combined. Wolf Steel and Simpson Dura-Vent venting systems must not be combined.

Venting terminals shall not be recessed into a wall or siding.

For optimum flame appearance and fireplace performance, keep the vent length and number of elbows to a minimum.

The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.

Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fireplace. Never obstruct the front opening of the fireplace.

W415-0619 / B / 03.03.08

Page 5
Image 5
Napoleon Fireplaces GT8N, Fireplace, GT8P manual Venting Lengths And Air Terminal Locations, Dimensions, FIGURES 1a-c